A failure incident of heat-exchange tubes in ammonia evaporators, which suffered from Received 7 October 2014 unexpected wall thinning after only one-year service with respect to their original design Received in revised form 13 January 2015 Accepted 13 January 2015 Available online 28 January 2015 lifetime of fifteen years, was reported and carefully analyzed. After overall inspection, many tube walls in the evaporators were found to experience severe degradations at both sides with distinct corroded defects and general cracking of corrosion layers. Thus, comprehensive investigations including external appearance, microscopic morphology and chemical.
机译:氨气蒸发器中的换热管发生故障事件,2014年10月7日收到,仅对其原始设计提供一年维修后壁意外变薄。2015年1月13日收到修订版。2015年1月13日接受。2015年1月28日在线。寿命长达十五年,已有报道并进行了认真分析。经过全面检查后,发现蒸发器中的许多管壁在两侧均出现严重退化,并出现明显的腐蚀缺陷和腐蚀层普遍开裂。因此,包括外观,微观形态和化学成分在内的综合研究。