摘要

Echocardiography is the most commonly applied technique for non-invasive assessment of cardiac function in small animals. Manual tracing of endocardial borders is time consuming and varies with operator experience. Therefore, we aimed to evaluate a novel automated two-dimensional software algorithm (Auto2DE) for small animals and compare it to the standard use of manual 2D-echocardiographic assessment (2DE). We hypothesized that novel Auto2DE will provide rapid and robust data sets, which are in agreement with manually assessed data of animals. 2DE and Auto2DE were carried out using a high-resolution imaging-system for small animals. First, validation cohorts of mouse and rat cine loops were used to compare Auto2DE against 2DE. These data were stratified for image quality by a blinded expert in small animal imaging. Second, we evaluated 2DE and Auto2DE in four mouse models and four rat models with different cardiac pathologies. Automated assessment of LV function by 2DE was faster than conventional 2DE analysis and independent of operator experience levels. The accuracy of Auto2DE-assessed data in healthy mice was dependent on cine loop quality, with excellent agreement between Auto2DE and 2DE in cine loops with adequate quality. Auto2DE allowed for valid detection of impaired cardiac function in animal models with pronounced cardiac phenotypes, but yielded poor performance in diabetic animal models independent of image quality. Auto2DE represents a novel automated analysis tool for rapid assessment of LV function, which is suitable for data acquisition in studies with good and very good echocardiographic image quality, but presents systematic problems in specific pathologies.
机译:超声心动图是用于小动物无创评估心脏功能的最常用技术。手动跟踪心内膜边界非常耗时,并且会随着操作员的经验而变化。因此,我们旨在评估一种针对小型动物的新颖的自动化二维软件算法(Auto2DE),并将其与手动2D超声心动图评估(2DE)的标准用法进行比较。我们假设新颖的Auto2DE将提供快速而强大的数据集,这与人工评估的动物数据一致。 2DE和Auto2DE是使用高分辨率成像系统对小型动物进行的。首先,将小鼠和大鼠电影环的验证队列用于比较Auto2DE与2DE。这些数据由小动物成像的盲人对图像质量进行了分层。其次,我们在具有不同心脏病理的四个小鼠模型和四个大鼠模型中评估了2DE和Auto2DE。 2DE对LV功能的自动评估比常规2DE分析要快,并且不受操作人员经验水平的影响。在健康小鼠中,Auto2DE评估的数据的准确性取决于电影环质量,而Auto2DE和2DE在具有足够质量的电影环中具有极好的一致性。 Auto2DE可以有效检测具有明显心脏表型的动物模型中的心脏功能受损,但在糖尿病动物模型中表现不佳,与图像质量无关。 Auto2DE代表了一种用于快速评估LV功能的新颖的自动化分析工具,适用于超声心动图图像质量非常好的研究中的数据采集,但在特定病理方面存在系统性问题。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号