摘要

The power generation of an exhaust TEG (thermoelectric generator) depends on heat energy and thermoelectric conversion efficiency. However, there are compatibility problems among TEG, CC (catalytic converter) and muf (muffler). The present work tried to vary the installation position of TEG and propose three different cases. Case 1: TEG is located at the end of the exhaust system; case 2: TEG is located between CC and muf; case 3: TEG is located upstream of CC and muf. Simulation and experiment were developed to compare thermal uniformity and pressure drop characteristics over the three operating cases. From the simulation and experiment, heat exchanger in case 2 obtained more uniform flow distribution, higher surface temperature and lower back pressure than in other cases. At the same time, the CC and muf could keep normal working in case 2, providing a theoretical and experimental basis for the exhaust gas waste heat recovery system.
机译:排气TEG(热电发生器)的发电取决于热能和热电转换效率。但是,TEG,CC(催化转化器)和muf(消声器)之间存在兼容性问题。当前的工作试图改变TEG的安装位置,并提出三种不同的情况。情况1:TEG位于排气系统的末端;情况2:TEG位于CC和muf之间;情况3:TEG位于CC和muf的上游。进行了仿真和实验,以比较三种操作情况下的热均匀性和压降特性。通过模拟和实验,与其他情况相比,情况2的热交换器具有更均匀的流量分布,更高的表面温度和更低的背压。同时,CC和muf可以在情况2下保持正常工作,为废气余热回收系统提供了理论和实验基础。