Objective: Rare diseaseBackground: Wearable smartphone-enabled cardiac monitoring devices can aid the diagnosis of asymptomatic tachycar-dia in neonates and infants. This report is of a rare case of left posterior fascicular ventricular tachycardia of Belhassen type detected in a neonate by ‘smart sock’ cardiac monitoring.Case Report: A premature baby boy at 37 weeks gestational age was discharged home after three days without complica-tion, and was given ‘smart socks’ to wear. He was followed up daily for the management of hyperbilirubine-mia, which was treated in the outpatient clinic with a phototherapy blanket. He was admitted to the emer-gency room (ER) at 6 days of age because his ‘smart socks’ identified a tachycardia of between 180–200 bpm. His parents reported no fever, cough, nasal congestion, or emesis. On examination in the ER, he was alert with no distress. An electrocardiogram (ECG) showed a sustained monomorphic and wide QRS tachycardia with a heart rate of 200 bpm, right bundle branch block (RBBB), and a superior axis that was compatible with a di-agnosis of left posterior fascicular ventricular tachycardia of Belhassen type. The echocardiogram showed a structurally normal heart with normal cardiac function. His tachycardia spontaneously converted to normal si-nus rhythm after four hours. He was discharged home three days later without further episodes of tachycar-dia. Cardiac monitoring using ‘ smart socks’ continued at home, and no further arrhythmias were detected at one year of age.Conclusions: The home use of smartphone-enabled technology to monitor the neonatal and infant cardiac heart rate can identify asymptomatic arrhythmias.
机译:目的:罕见疾病背景:可穿戴的启用智能手机的心脏监测设备可以帮助诊断新生儿和婴儿的无症状心动过速。该报告是一例罕见的病例,通过“智能袜子”心脏监测在新生儿中发现Belhassen型左后筋膜室性心动过速。病例报告:胎龄为37周的早产男婴三天无并发症后出院。 ,并穿着“智能袜”。每天对他进行随访,以管理高胆红素血症,该病在门诊使用光疗毯进行治疗。他6岁大的时候就被送入急诊室(ER),因为他的“智能袜子”识别出的心动过速为180-200 bpm。他的父母没有发烧,咳嗽,鼻塞或呕吐。在急诊室检查时,他警觉而未受任何困扰。心电图(ECG)显示持续单态性和宽QRS心动过速,心率200 bpm,右束支传导阻滞(RBBB),上轴与Belhassen型左后筋膜室性心动过速兼容。超声心动图显示心脏结构正常,心脏功能正常。四小时后,他的心动过速自发转变为正常的窦性心律。三天后他出院回家,没有进一步的心动过速发作。在家中继续使用“智能袜子”进行心脏监护,一岁时未发现进一步的心律失常。结论:在家中使用支持智能手机的技术来监测新生儿和婴儿心率,可以识别出无症状的心律失常。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号