首页> 外文期刊>Buildings >Comparison of Infrared Thermography and Heat Flux Method for Dynamic Thermal Transmittance Determination
【24h】

Comparison of Infrared Thermography and Heat Flux Method for Dynamic Thermal Transmittance Determination

机译:动态热透射率测定中红外热成像和热通量方法的比较

获取原文
       

摘要

This paper proposes an alternative experimental procedure that uses infrared thermography (IRT) for measuring the surface temperature of building elements, through which it is possible to approximate the thermal transmittance or the U-value. The literature review showed that all authors used similar procedures that require semi-stationary heat transfer conditions, which, in most cases, could not be achieved. The dynamic and the average methods that are given in ISO 9869 were also used with the IRT and the heat flux method (HFM). The dynamic method (DYNM) shows a higher level of accuracy compared to the average method (AVGM). Since the algorithm of the DYNM is more complicated than that of the AVGM, Microsoft Excel VBA was used to implement the algorithm of the DYNM. Using the procedure given in this paper, the U-value could be approximated within 0–30% of the design U-value. The use of IRT, in combination with the DYNM, could be used in-situ since the DYNM does not require stable boundary conditions. Furthermore, the procedure given in this paper could be used for relatively fast and inexpensive U-value approximation without the use of expensive equipment (e.g., heat flux sensors).
机译:本文提出了一种替代性的实验程序,该程序使用红外热成像(IRT)来测量建筑构件的表面温度,通过该程序可以估算热透射率或U值。文献综述表明,所有作者都使用了类似的程序,这些程序需要半平稳的传热条件,在大多数情况下,这是无法实现的。 IRT和热通量方法(HFM)也使用了ISO 9869中给出的动态和平均方法。与平均方法(AVGM)相比,动态方法(DYNM)显示出更高的准确性。由于DYNM的算法比AVGM的算法复杂,因此使用Microsoft Excel VBA来实现DYNM的算法。使用本文给出的步骤,U值可以近似于设计U值的0–30%。由于DYNM不需要稳定的边界条件,因此可以将IRT与DYNM结合使用。此外,本文中给出的过程可用于相对快速和廉价的U值近似,而无需使用昂贵的设备(例如,热通量传感器)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号