首页> 外文期刊>Canadian Urological Association Journal >Diagnosis of testicular torsion using near infrared spectroscopy: A novel diagnostic approach
【24h】

Diagnosis of testicular torsion using near infrared spectroscopy: A novel diagnostic approach

机译:近红外光谱法诊断睾丸扭转的新方法

获取原文
           

摘要

We report a case of testicular torsion in a 14-month old boy. Testicular ischemia was suspected based on history and clinical presentations. The patient was referred following 24 hours of left acute scrotum. Erythema, swelling and tenderness associated with nausea and emesis were present, but the patient was not febrile. We used a spatially resolved near-infrared spectroscopy (SR-NIRS) device to study and compare the tissue saturation index (TSI) on both right and left spermatic cords. The TSI was significantly reduced in the left side. Both testicles were surgically explored and the left testis was found non-viable with a 1080-degree intra-vaginal torsion. NIRS monitoring of spermatic cord oxygen saturation appears feasible as a non-invasive bedside optical method to identify testicular torsion.
机译:我们报告了一个14个月大男孩的睾丸扭转病例。根据病史和临床表现怀疑睾丸缺血。左急性阴囊24小时后转诊该患者。伴有恶心和呕吐的红斑,肿胀和压痛,但患者不发热。我们使用空间分辨近红外光谱仪(SR-NIRS)来研究和比较左右精索的组织饱和指数(TSI)。左侧的TSI显着降低。手术探查了两个睾丸,发现左侧睾丸不可行,并伴有1080度阴道内扭转。 NIRS监测精索氧饱和度作为一种非侵入性床旁光学方法来鉴定睾丸扭转似乎是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号