首页> 外文期刊>Brazilian Journal of Physical Therapy >Influence of pursed-lip breathing on heart rate variability and cardiorespiratory parameters in subjects with chronic obstructive pulmonary disease (COPD)
【24h】

Influence of pursed-lip breathing on heart rate variability and cardiorespiratory parameters in subjects with chronic obstructive pulmonary disease (COPD)

机译:chronic唇式呼吸对慢性阻塞性肺疾病(COPD)患者心率变异性和心肺参数的影响

获取原文
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: To assess the effects of pursed-lip breathing (PLB) at rest on the behavior of heart rate (HR) and its variability, and on variations in blood pressure (BP), respiratory rate (RR) and pulse oxygen saturation (SpO2) in subjects with chronic obstructive pulmonary disease (COPD). METHODS: Sixteen subjects with COPD (seven in GOLD stage I, three in GOLD stage II and six in GOLD stage III; mean age 64±11 years; mean FEV1 60±25% of predicted value) were assessed at rest, in a seated position, under the following conditions: ten minutes of normal breathing without PLB (R1), eight minutes with PLB (R2) and ten minutes of normal breathing once more (R3). HR was recorded, beat-to-beat, by means of a Polar S810 heart monitor. The RMSSD index (root mean square of the difference between successive R-R intervals) was determined. BP, RR and SpO2 were also assessed during the trials. ANOVA for repeated measures followed by the Tukey test and Kruskal-Wallis test were used for data analysis, with a 5% significance level. RESULTS: There was a significant increase in the RMSSD index during R2, in comparison with R1. The HR variation between inspiration and expiration was 8.98 bpm, and the variation between HR at rest and HR with PLB was 8.25 bpm. During R2, RR decreased and SpO2 increased significantly in comparison with R1 and R3. BP values did not show significant changes. CONCLUSIONS: The results showed that PLB produced significant changes in HR, RR and SpO2, and did not alter BP in subjects with COPD. Furthermore, analysis of the RMSSD index showed that PLB promoted increased parasympathetic activity in these subjects, thus indicating that this technique influenced the autonomic cardiac modulation.
机译:目的:评估静息双唇呼吸对心率(HR)行为及其变异性,血压(BP),呼吸率(RR)和脉搏血氧饱和度(SpO2)的影响)患有慢性阻塞性肺疾病(COPD)的受试者。方法:在坐着的情况下,评估了16名COPD受试者(第一阶段为七名,第二阶段为三名,第三阶段为六名;平均年龄64±11岁;平均FEV1为预测值的60±25%)。在以下情况下保持姿势:无PLB的正常呼吸时间为10分钟(R1),有PLB的正常呼吸时间为8分钟(R2),再次有10分钟的正常呼吸时间为(R3)。通过Polar S810心脏监护仪逐次记录心率。确定了RMSSD指数(连续R-R间隔之间的差的均方根)。试验期间还评估了BP,RR和SpO2。采用重复测量的方差分析,然后进行Tukey检验和Kruskal-Wallis检验进行数据分析,显着性水平为5%。结果:与R1相比,R2期间RMSSD指数显着增加。吸气和呼气之间的HR变化为8.98 bpm,静息HR和PLB HR之间的HR变化为8.25 bpm。与R1和R3相比,R2期间RR降低,SpO2显着增加。 BP值未显示明显变化。结论:结果显示,在COPD患者中,PLB在HR,RR和SpO2方面产生了显着变化,并且没有改变BP。此外,对RMSSD指数的分析表明,PLB在这些受试者中促进了副交感神经活动的增强,因此表明该技术影响了自主心脏的调节。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号