...
首页> 外文期刊>BMC Psychiatry >Translation and validation of the Korean confusion assessment method for the intensive care unit
【24h】

Translation and validation of the Korean confusion assessment method for the intensive care unit

机译:重症监护病房韩语混淆评估方法的翻译和验证

获取原文

摘要

Background Delirium is a common problem and associated with poor outcomes in intensive care unit (ICU) patients. Diagnosis of delirium in ICU patients is limited and usually underdiagnosed by physicians. The Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) is one of the most widely used screening methods for detection of ICU delirium. Our goal was to translate and validate the CAM-ICU for use in the Korean ICU setting. Methods Translation of the CAM-ICU was done according to the guidelines suggested by the Translation and Cultural Adaptation Group. For validation and interrater reliability assessment of the Korean CAM-ICU, two nurses independently assessed delirium in ICU patients and the results were compared with the reference evaluation, which was done by a psychiatrist using the Diagnostic and Statistical Manual of Mental Disorders IV (DSM-IV). Results Twenty-two patients were evaluated by two nurses and one psychiatrist expert independently. During the study period, we have continuously educated study nurses. Based on DSM-IV criteria, 16 out of 22 (72.7%) patients developed delirium. The sensitivities of the two nurses' evaluations using the Korean CAM-ICU were 89.80% for nurse 1 and 77.40% for nurse 2. Their specificities were 72.40% and 75.80% and their overall accuracy was 83.33% and 88.37% respectively. The Korean CAM-ICU was done with reasonable interrater reliability between nurse 1 and nurse 2 (κ = 0.81, p Conclusions The Korean CAM-ICU showed good validity and could be incorporated into clinical practice in Korean ICUs. Trial registration ISRCTN: ISRCTN50265663
机译:背景Deli妄是一个常见问题,与重症监护病房(ICU)患者的不良结局有关。重症监护病房患者的limited妄诊断是有限的,通常被医生诊断不足。重症监护病房(CAM-ICU)的混淆评估方法是用于检测ICU ir妄的最广泛使用的筛查方法之一。我们的目标是翻译和验证CAM-ICU以用于韩国ICU设置。方法CAM-ICU的翻译按照翻译和文化适应小组的建议进行。为了验证和验证韩国CAM-ICU的人间可靠性,两名护士对ICU患者的del妄进行了独立评估,并将结果与​​参考评估进行了比较,该评估由精神科医生使用《精神疾病诊断和统计手册IV》(DSM- IV)。结果22名患者分别由2名护士和1名精神科医生进行了评估。在学习期间,我们不断地对学习护士进行培训。根据DSM-IV标准,22名患者中有16名(72.7%)出现del妄。两名护士使用韩国CAM-ICU进行评估的敏感性分别为:护士1为89.80%,护士2为77.40%。特异性为72.40%和75.80%,总体准确度分别为83.33%和88.37%。韩国CAM-ICU在护士1和护士2之间具有合理的间隔可靠性(κ= 0.81,p)结论韩国CAM-ICU表现出良好的有效性,可以在韩国重症监护病房的临床实践中使用。试用注册ISRCTN:ISRCTN50265663

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号