首页> 外文期刊>BMC Musculoskeletal Disorders >Treatment of the surgical neck fracture of the humerus with a novel external fixator in the elderly with osteoporosis: biomechanical analysis
【24h】

Treatment of the surgical neck fracture of the humerus with a novel external fixator in the elderly with osteoporosis: biomechanical analysis

机译:新型骨质疏松症外固定架治疗肱骨外科颈骨折的生物力学分析

获取原文
           

摘要

No consensus exists on the treatment of proximal humerus fractures, especially in the elderly patients with osteoporosis. This study was aimed to evaluate the biomechanical characteristics of a novel external fixator in treating two-part surgical neck fracture of the proximal humerus in the elderly patients with osteoporosis. Sixteen female elderly humeral shaft specimens with osteoporosis were randomized into 2 groups. Models with the surgical neck two-part fracture of the proximal humerus were built, in which a novel external fixator (test group) and a clover plate (control group) were applied separately. In the test group, the fracture was firstly fixed with intersection pinning using 3 Schanz pins (3.5?mm), followed by the novel external fixation frame. In the control group, a clover plate and 6 cortical bone screws were applied. Biomechanical testing of the specimens was performed to assess the resistance to load bearing and torsional stress. The parameters of the two groups were compared using independent t-test. Ultimate bearing capacity and load bearing at different parts with the humerus rotation were higher (P??0.05) in the external fixator group (145.16?±?17.42?N and 140?N respectively) than those in the plate group (120.21?±?13.15?N and 69.63?±?25.16–90.78?±?17.18?N respectively). As for resistance to torsional stress, plate’s torque fluctuated between 1?Nm and 5?Nm, while the external fixator’s torque values were more evenly (P??0.01) distributed with the fluctuation within 1?Nm. In the fixation of two-part humeral fracture in elderly patients with osteoporosis, the new external fixator seemed to be superior to plate fixation in load bearing and resistance to torsional stress.
机译:对于肱骨近端骨折的治疗尚无共识,尤其是在老年骨质疏松症患者中。这项研究的目的是评估一种新型外固定器在治疗老年骨质疏松症患者肱骨近端的两部分式手术性颈部骨折中的生物力学特性。将16例女性老年肱骨干骨质疏松标本随机分为2组。建立具有肱骨近端手术颈部两部分骨折的模型,其中分别应用新型外固定器(试验组)和三叶草板(对照组)。在测试组中,首先使用3个Schanz销钉(3.5?mm)通过交叉钉固定骨折,然后再使用新颖的外固定架。对照组采用三叶草板和6个皮质骨螺钉。对样品进行了生物力学测试,以评估其对承载力和扭转应力的抵抗力。使用独立的t检验比较两组的参数。外固定架组(分别为145.16±±17.42?N和140?N)随肱骨旋转的不同部位的极限承载力和承重均高于钢板组(120.21?P)。分别为±?13.15?N和69.63?±?25.16–90.78?±?17.18?N。至于抗扭应力,板的扭矩在1?Nm和5?Nm之间波动,而外固定器的扭矩值分布更均匀(P 0.01),波动在1?Nm以内。在老年骨质疏松患者的肱骨两部分骨折固定中,新的外固定器似乎在承重和抗扭转应力方面优于钢板固定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号