首页> 外文期刊>BMC Musculoskeletal Disorders >Reliability of quantifying the spatial distribution of fatty infiltration in lumbar paravertebral muscles using a new segmentation method for T1-weighted MRI
【24h】

Reliability of quantifying the spatial distribution of fatty infiltration in lumbar paravertebral muscles using a new segmentation method for T1-weighted MRI

机译:使用T1加权MRI新分割方法量化腰椎旁脂肪中脂肪浸润的空间分布的可靠性

获取原文

摘要

Background To our knowledge, there are no methods allowing for quantification of the spatial distribution of lumbar paravertebral muscle fatty infiltration (FI) in the transverse plane. There is an increasing emphasis on muscle tissues as modifiable factors in lumbar spine health. Population datasets based on conventional T1-weighted (T1-W) magnetic resonance imaging (MRI) represent a valuable resource for examining all spinal tissues, and methods with reliability are needed. The aim of our study was to determine the reliability of a novel method quantifying lumbar paravertebral muscle fat content based on conventional T1-W MRI. Methods Axial 3-Tesla T1W MRIs from ten adult subjects (3W, 7M; mean age 52.8?±?SD 7.2 years) were randomly selected from the large prospective cross-sectional Hong Kong Population-based Disc Degeneration Cohort study examining lumbar spine degeneration. The selected sample included subjects with mixed imaging-determined disc degeneration and low back pain history. Two raters with MRI lumbar paravertebral muscle analysis experience (R1?>?250 h and R2?>?1000 h) repeat-measured the image-set a week apart. Multifidus and erector spinae (spinalis, longissimus and iliocostalis) were manually outlined together on a single-slice from the inferior vertebral end-plates of L1 to L5 using a semi-automated, quartile-defining (Q1-4 (medial to lateral) and Qmean) MatLab-based programme. Bland-Altman plots and intra-class correlation coefficients (ICC) with 95 % confidence intervals (CI) describe intra- and inter-rater reliability according to lumbar level, quartile, and side, and combined level and quartile. Results There was good intra- (ICC?=?0.88; CI: 0.87–0.90) and inter-rater agreement (ICC?=?0.82; CI: 0.80–0.84). Intra-rater values for Qmean (ICC; CI) were higher at L5 (0.89; 0.79–0.94) than L1 (0.61; 0.37–0.78). Higher intra-rater values for L1-5 were shown at Q1 (0.93; 0.91–0.95) than Q3 (0.83; 0.78–0.87) or Q4 (0.81; 0.76–0.85), and on the right (0.91; 0.90–0.93) than left (0.85; 0.83–0.88). Similar observations were made for inter-rater values in terms of lumbar level and quartile, with no differences between sides shown. Conclusions In our study of ten cases we demonstrate a reliable method to quantify the spatial distribution of fat content in lumbar paravertebral muscles based on T1W MRI. Understanding the geography of fat content in these muscles may offer additional insight in determining and improving spinal health. The clinical relevance and application of this method require testing across various populations to build on the early feasibility established in this study.
机译:背景技术据我们所知,目前尚无方法可量化腰椎横断面中腰椎旁肌肉脂肪浸润(FI)的空间分布。人们越来越重视肌肉组织作为腰椎健康中的可调节因素。基于常规T1加权(T1-W)磁共振成像(MRI)的人群数据集是检查所有脊柱组织的宝贵资源,因此需要可靠的方法。我们研究的目的是确定一种基于常规T1-W MRI定量腰椎旁椎间脂肪含量的新方法的可靠性。方法从大型前瞻性横断面香港人群椎间盘退变队列研究中随机抽取十名成人受试者(3W,7M;平均年龄52.8±±SD 7.2岁)的轴向3-Tesla T1W MRI检查腰椎变性。选择的样本包括具有混合成像确定的椎间盘退变和腰痛史的受试者。两名具有MRI腰椎旁肌分析经验的评估者(R1→> 250小时,R2→> 1000小时)隔周重复测量图像集。使用半自动四分位定义(Q1-4(内侧至外侧)和半自动),在L1至L5的下椎终板的单片上手动勾勒出多裂棘突和竖脊棘(棘突,脊突和i肋) Q mean )基于MatLab的程序。具有95%置信区间(CI)的Bland-Altman图和类别内相关系数(ICC)根据腰椎水平,四分位数和侧面以及合并的水平和四分位数描述了评分者内部和评分者之间的可靠性。结果良好的内部(ICC = 0.88; CI:0.87-0.90)和评分者之间的一致性(ICC = 0.82 = 0.82; CI:0.80-0.84)。 Q <均值(ICC; CI)的评分者内值在L5(0.89; 0.79–0.94)高于L1(0.61; 0.37–0.78)。在第1季度(0.93; 0.91–0.95),与第3季度(0.83; 0.78–0.87)或第4季度(0.81; 0.76–0.85)相比,L1-5的内部评级者值更高,在右侧(0.91; 0.90–0.93)比左(0.85; 0.83-0.88)。对于腰间水平和四分位数的评分者间值进行了类似的观察,未显示两侧之间的差异。结论在对10例病例的研究中,我们证明了一种基于T1W MRI量化腰椎旁肌肉脂肪含量空间分布的可靠方法。了解这些肌肉中脂肪含量的地理位置可能会为确定和改善脊柱健康提供更多的见解。此方法的临床相关性和应用要求在各个人群中进行测试,以建立在这项研究中建立的早期可行性上。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号