首页> 外文期刊>BMC Musculoskeletal Disorders >Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration
【24h】

Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration

机译:实时剪切波超声弹性成像测量的上睑肌弹性与MRI光谱测量的脂肪变性相关

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly. Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson’s correlation test. Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0% to 77.41% and SWV from 1.59?m/s to 5.32?m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle. These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS. Ethical Committee Approval: Nr: 156/14 Date 12th August 2014. Level of Evidence: III.
机译:肩袖肌肉的脂肪变性(FD)影响肩袖修复后的功能和解剖结果。基于MRI的脂肪变性评估是金标准。有一些证据表明,超声弹性成像(EUS)可以检测肌肉和肌腱组织刚度的局部差异。评估了剪切波弹性成像(SWE),以确定剪切波速度与脂肪变性测量值相关的程度。 MRI光谱脂肪测量被用作量化腹部肌肉脂肪的参考。 42名患者接受了最大直径的棘上肌SWE。超声评估后,使用SPLASH技术对棘上肌进行MRI光谱脂肪测量。使用凝胶填充的胶囊在MRI中定位测量区域。使用皮尔森相关检验,将通过SWE和光谱脂肪测量得到的剪切波速度(SWV)值进行统计相关。用MRI光谱法测得的脂肪量与用SWE法测得的SWV的相关值为ρ= 0.82。用光谱法测得的棘上肌的脂肪比率为0%至77.41%,SWV为1.59?m / s至5.32?m / s。在4例患者中,无法进行足够的SWE,这些患者的上皮软组织直径较大。用SWE测量的SWV与脊柱上肌的MRI光谱脂肪量显示出良好的相关性。这些初步数据表明,SWE可能是实时检测和估计上棘上肌脂肪变性量的足够工具。较大的上覆软组织可能是进行足够的EUS的限制。伦理委员会批准:编号:156/14,日期:2014年8月12日。证据等级:III。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号