首页> 外文期刊>BioMedical Engineering OnLine >Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study
【24h】

Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study

机译:基于ppg形态的无创血压估计的可行性研究:血压正常的研究

获取原文
           

摘要

Background Blood pressure is a critical bio-signal and its importance has been increased with the aged society and the growth of cardiovascular disease population. However, most of hypertensive patients have been suffered the inconvenience in monitoring blood pressure in daily life because the measurement of the blood pressure depends on the cuff-based technique. Nowadays there are many trials to measure blood pressure without cuff, especially, photoplethysmography (PPG) based research is carried out in various ways. Methods Our research is designed to hypothesis the relationship between vessel wall movement and pressure-flow relationship of PPG and to validate its appropriateness by experimental methods. PPG waveform is simplified by approximate model, and then it is analyzed as the velocity and the acceleration of blood flow using the derivatives of PPG. Finally, we develop pressure index (PI) as an estimation factor of blood pressure by combining of statistically significant segments of photoplethysmographic waveform. Results Twenty-five subjects were participated in the experiment. As a result of simulation, correlation coefficients between developed PI and blood pressure were represented with R =?0.818, R =?0.827 and R =?0.615 in systolic blood pressure, pulse pressure and mean arterial pressure, respectively, and both of result showed the meaningful statistically significance ( P Conclusions Current study can estimate only the relative variation of blood pressure but could not find the absolute pressure value. Moreover, proposed index has the limitation of diastolic pressure tracing. However, the result shows that the proposed PI is statistically significantly correlated with blood pressures, and it suggests that the proposed PI as a promising additional parameter for the cuff less blood pressure monitoring.
机译:背景技术血压是至关重要的生物信号,随着社会的老龄化和心血管疾病人口的增长,血压的重要性日益提高。然而,由于血压的测量取决于基于袖带的技术,因此大多数高血压患者在日常生活中难以监测血压。如今,有许多不使用袖带测量血压的试验,尤其是以光体积描记法(PPG)为基础的研究以各种方式进行。方法我们的研究旨在假设PPG的血管壁运动与压力-流量关系之间的关系,并通过实验方法验证其适用性。通过近似模型简化PPG波形,然后使用PPG的导数将其作为血流的速度和加速度进行分析。最后,我们通过结合光电容积描记波形的统计显着部分来开发压力指数(PI)作为血压的估计因子。结果共有25名受试者参加了实验。作为模拟的结果,在收缩压,脉压和平均动脉压中,分别将R =?0.818,R =?0.827和R =?0.615表示发展的PI与血压之间的相关系数,并且两者均显示有意义的统计学意义(P结论当前的研究只能估计血压的相对变化,而无法找到绝对压力值。此外,所提出的指标具有舒张压追踪的局限性。但是,结果表明所提出的PI具有统计学意义与血压显着相关,这表明拟议的PI可作为无袖带血压监测的有希望的附加参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号