首页> 外文期刊>Brazilian Journal of Cardiovascular Surgery >Comparison of Arterial Repair through the Suture, Suture with Fibrin or Cyanoacrylate Adhesive in Ex-Vivo Porcine Aortic Segment
【24h】

Comparison of Arterial Repair through the Suture, Suture with Fibrin or Cyanoacrylate Adhesive in Ex-Vivo Porcine Aortic Segment

机译:体外主动脉段通过缝线,纤维蛋白或氰基丙烯酸酯缝线进行动脉修复的比较

获取原文
       

摘要

Abstract Introduction: Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective: To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods: 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results: In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002). In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002). Intraluminal adhesive penetration has not been noticed. Conclusion: There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries.
机译:摘要简介:组织粘合剂可以与缝合线相邻使用,以降低或避免心血管手术中的出血。目的:验证纤维蛋白和氰基丙烯酸酯粘合剂密封动脉缝合线以及粘合剂是否通过缝合线渗透到动脉内部的效率。方法:将20只猪的腹主动脉段根据胶粘剂分为两组,将其与缝合线相邻。在每个动脉节段中,都要进行动脉切开术,然后进行常规的动脉闭合术。然后,将胶体液注入动脉段内,同时进行血管内压力监测,直至通过缝线渗漏。在缝线上施加一种粘合剂后,重复此过程,以检查破裂压力是否增加。还分析了主动脉内段,以检查是否存在腔内粘合剂渗透。结果:缝合线1组中,动脉缝合线所承受的平均动脉压达到86±5.35 mmHg,而施加纤维蛋白胶后达到104±11.96(P <0.002)。在缝合线2组中,缝合线所承受的平均动脉压达到83±2.67 mmHg,在应用氰基丙烯酸酯粘合剂后达到152±14.58 mmHg(P <0.002)。尚未发现管腔内粘合剂的渗透。结论:当使用组织粘合剂与动脉缝合线相邻时,破裂压力显着升高,如果使用氰基丙烯酸酯粘合剂,则该升高更高。此外,粘合剂不会穿过缝合线渗入动脉。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有