...
首页> 外文期刊>BMC Veterinary Research >Measurement variability of right atrial and ventricular monophasic action potential and refractory period measurements in the standing non-sedated horse
【24h】

Measurement variability of right atrial and ventricular monophasic action potential and refractory period measurements in the standing non-sedated horse

机译:站立的非镇静马匹的右心房和心室单相动作电位的测量变异性和不应期

获取原文
           

摘要

In human and veterinary medicine, monophasic action potential (MAP) analysis and determination of local refractory periods by contact electrode technique gives valuable information about local cardiac electrophysiological properties. It is used to investigate dysrhythmias and the impact of drugs on the myocardium. Precise measurement of total MAP duration is difficult, therefore the MAP duration is usually determined at a repolarization level of 90% (APD90). Until now, no studies are published about the feasibility of this technique in the standing non-sedated horse. In 6 healthy Warmblood horses, on two different days, an 8F quadripolar contact catheter was passed through a jugular introducer sheath and placed under ultrasound guidance at the level of the intervenous tubercle or right atrial free wall (RA), and in the right ventricular apex (RV) to record the MAP. The MAP amplitude and APD90 were measured at a resting sinus rhythm (heart rate of 30-42?bpm) and at pacing cycle lengths (PCL) of 1000 and 600?ms. The effective refractory period (ERP) was determined at PCL of 1000 and 600?ms. The overall mean (±SD) APD90 (rest), APD90 (1000) and APD90 (600) were 263?±?39?ms, 262?±?41?ms, 236?±?47?ms for the RA and 467?±?23?ms, 412?±?38?ms, 322?±?29?ms for the RV. The mean ERP1000 and ERP600 were 273?±?24?ms and 256?±?22?ms for the RA and 386?±?40?ms and 293?±?30?ms for the RV. The measurement variability for the amplitude, APD90 and ERP measurements in the RA ranged between 36 and 44, 9–22 and 7–8%, respectively. The measurement variability for the amplitude, APD90 and ERP measurements in the RV ranged between 49 and 66, 6–7 and 10–12%, respectively. RA and RV MAP duration and ERP can be obtained by a contact electrode in standing non-sedated horses. The measurement variability varies with catheter location.
机译:在人类和兽医学中,单相动作电位(MAP)分析和通过接触电极技术确定局部不应期可提供有关局部心脏电生理特性的有价值的信息。它用于检查心律不齐和药物对心肌的影响。精确测量总MAP持续时间很困难,因此MAP持续时间通常以90%的复极化水平(APD90)确定。到目前为止,尚未发表关于这种技术在站立的非镇静马匹中的可行性的研究。在两天中,在6头健康的Warmblood马中,将一条8F四极接触导管穿过颈静脉导引鞘,并在超声引导下于结节或右房游离壁(RA)的水平以及右心室顶点放置(RV)记录MAP。在静息窦性心律(心律为30-42?bpm)和起搏周期长度(PCL)为1000和600?ms的情况下测量MAP幅度和APD90。在PCL为1000和600?ms时确定有效不应期(ERP)。 APD90(其余),APD90(1000)和APD90(600)的总体平均(±SD)为263?±?39?ms,262?±?41?ms,236?±?47?ms和467? RV为±23度,412±38度,322±29度。 RA的平均ERP1000和ERP600为273?±?24?ms和256?±?22?ms,RV的平均为386?±?40?ms和293?±?30?ms。 RA中的振幅,APD90和ERP测量的测量变异性分别在36和44、9-22和7-8%之间。 RV中振幅的测量变异性,APD90和ERP测量的变异性分别在49%和66%,6-7%和10-12%之间。 RA和RV MAP的持续时间以及ERP可以通过站立的非镇静马匹中的接触电极获得。测量变异性随导管位置而变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号