首页> 外文期刊>BMJ Open Quality >Reducing radiation hazard opportunities in neonatal unit: quality improvement in radiation safety practices
【24h】

Reducing radiation hazard opportunities in neonatal unit: quality improvement in radiation safety practices

机译:减少新生儿部门的辐射危害机会:提高辐射安全实践的质量

获取原文
           

摘要

Aim Guided by the ALARA - "As Low As Reasonably Achievable" principle in radiation safety, a quality improvement project to optimise the bedside diagnostic imaging process to the best standards of care was conducted over a six month period. The goal was too reduce the radiation hazard opportunities in the neonatal intensive care unit by at least 75% from the existing level at Q2/2015, within 6 months.Methods The existing bedside imaging process was critically analysed and the following quality improvement initiatives were implemented namely , mandatory lead protective gear to healthcare staff, gonadal shield for neonates, guidelines for optimal collimation of X-ray beam and optimal positioning of neonates. Radiation dosimetry results, regular staff awareness sessions and strong collaboration between neonatologists, radiologists, radiographers and neonatal nurses helped to ensure compliance to the revised imaging process. Radiation hazard opportunities were measured by analysing all radiographs done during the period under baby exposure and healthcare staff exposure categories.Summary of results Radiation hazard opportunities were reduced by 100% to healthcare staff and 75% to neonates, and the overall reduction was 83%. The rate of discordance between radiograph request forms and images taken was measured as a surrogate marker for compliance to the project initiatives and it declined by 77%. Mandatory orientation of staff to the revised policy on the standardised diagnostic imaging process, regular radiation awareness talks and staff feedback sessions are among several measures taken to sustain the project.
机译:在ALARA的指导下-辐射安全的“尽可能低到可以合理实现”的原则,在六个月的时间内进行了一项质量改进项目,以优化床边诊断成像过程,使其达到最佳护理标准。目标是在6个月内将新生儿重症监护病房的放射危害机会与2015年第二季度的现有水平相比至少减少75%。方法严格分析了现有的床旁成像过程,并实施了以下质量改进措施包括对医护人员的强制性铅防护装备,新生儿的性腺防护罩,X射线束的最佳准直和新生儿的最佳定位指南。辐射剂量测定结果,定期的员工意识培训以及新生儿科医生,放射科医生,放射线照相师和新生儿护士之间的密切合作,有助于确保符合修订后的成像过程。通过分析婴儿暴露和医护人员暴露类别下的所有X光片来测量放射危害机会。结果摘要放射危害机会对医护人员减少了100%,对新生儿减少了75%,总体减少了83%。射线照相申请表和所拍摄图像之间的不一致率被衡量为符合项目计划的替代标志,并且下降了77%。为了使该项目得以维持,已采取了多项措施,要求工作人员对标准化诊断成像过程的修订政策进行强制性定向,定期进行辐射意识讲座和工作人员反馈会议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号