首页> 外文期刊>BMC Endocrine Disorders >Impact of diabetes mellitus on functional exercise capacity and pulmonary functions in patients with diabetes and healthy persons
【24h】

Impact of diabetes mellitus on functional exercise capacity and pulmonary functions in patients with diabetes and healthy persons

机译:糖尿病对糖尿病患者和健康人功能运动能力和肺功能的影响

获取原文
           

摘要

Chronic diabetic complications may afflict all organ tissues, including those of the respiratory system. The six-minute walk test (6MWT) is an alternative and widely used method of assessing functional capacity and is simple to perform. However, to our knowledge, the impact of diabetes mellitus on 6MWT performance has not been investigated previously. This research aimed to compare the functional exercise capacity and pulmonary functions in patients with diabetes and in healthy persons. The study included 131 participants: 64 patients with type 1 and 2 diabetes mellitus (DM) and 67 healthy participants (CG). All of the participants were nonsmoking and did not have pulmonary disorders that affected the pulmonary function tests or 6MWT. Metabolic parameters and biochemical markers of inflammation were assessed. Full lung function tests and a 6MWT were performed. In the DM group, the walking distance was 109?m shorter than that in the CG (P??0.001). Moreover, compared to the CG, the DM group showed lower values of forced expiratory volume in one second (FEV1 (l) 3.6 vs. 2.8, P??0.001) and total lung capacity (TLC (l) 6.6 vs. 5.6, P??0.001), as well as a decrease in diffusion capacity (DLCO (mmol/min/kPa), 10.0 vs. 8.6, P??0.001). The 6MWT is a valuable test that complements the assessment of daily physical capacity in patients with diabetes, irrespective of type. Pulmonary function and the capacity for physical exertion varied between patients with diabetes mellitus and the healthy participants in the CG.
机译:慢性糖尿病并发症可能会影响所有器官组织,包括呼吸系统器官。六分钟步行测试(6MWT)是另一种广泛使用的评估功能能力的方法,并且操作简单。然而,据我们所知,糖尿病尚未对6MWT性能产生影响。这项研究旨在比较糖尿病患者和健康人的功能锻炼能力和肺功能。该研究包括131名参与者:64名1型和2型糖尿病(DM)患者和67名健康参与者(CG)。所有参与者均禁止吸烟,并且没有影响肺功能测试或6MWT的肺部疾病。评估了炎症的代谢参数和生化指标。进行了全肺功能测试和6MWT。 DM组的步行距离比CG组的步行距离短109μm(P≤0.001)。此外,与CG相比,DM组的一秒钟强迫呼气量值较低(FEV1(l)3.6 vs. 2.8,P 0.001)和总肺容量(TLC(l)6.6 vs. 5.6, P 2 <0.001,以及扩散能力的降低(DLCO(mmol / min / kPa),10.0对8.6,P 2 <0.001)。 6MWT是一种有价值的测试,可补充对糖尿病患者的日常体力评估,无论其类型如何。糖尿病患者和CG健康参与者之间的肺功能和体育锻炼能力各不相同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号