首页> 外文期刊>BMC Ophthalmology >Quantitative comparisons of ultra-widefield images of model eye obtained with Optos ? 200Tx and Optos ? California
【24h】

Quantitative comparisons of ultra-widefield images of model eye obtained with Optos ? 200Tx and Optos ? California

机译:使用Optos®获得的模型眼的超广角图像的定量比较200Tx和光电?加利福尼亚州

获取原文
获取外文期刊封面目录资料

摘要

To compare the quality of the ultra-widefield images acquired by Optos? 200Tx to those acquired by Optos? California. Images of the posterior surface of a Gullstrand’s model eye obtained by Optos? 200Tx were compared to those obtained by Optos? California in terms of the angular field of view and the symmetry of the image, i.e., vertical and horizontal aspect ratios at the center (0°) and at the periphery (40° and 80°) in each direction. In addition, we compared the enlargement of the image on the posterior surface as the square ratio, and the differences in the contrasts. No significant differences were detected in the angular field of view between the two instruments. The aspect ratios showed that the Optos? California had more symmetrical images than the Optos? 200Tx at the center (0.98 vs 0.89, P??0.01) and at the 40° periphery (0.93–1.04, △0.11 vs 0.79–1.01, △0.22) and 80° periphery (0.81–1.25, △0.44 vs 0.42–1.12, △0.70) in each direction. The amplitude of the square ratio of the Optos? California was smaller at 40° periphery (1.16–1.28, △0.12 vs 1.06–1.37, △0.31) and 80° periphery (2.12–2.46, △0.34 vs 1.14–3.29, △2.15). The contrast of the Optos? California images was significantly higher in the posterior pole (0.09 vs 0.12, P??0.01), upper (0.07 vs 0.03, P??0.01), and right (0.12 vs 0.07, P??0.01) peripheries. Optos? California can record equal angular widefield images to Optos? 200Tx and more symmetrical images with higher contrast in the posterior pole, upper and right peripheries.
机译:比较Optos采集的超广角图像的质量? 200倍于Optos收购的交易量?加利福尼亚由Optos获得的Gullstrand模型眼的后表面图像?将200Tx与通过Optos获得的那些进行了比较。在角度视场和图像对称性方面,即在每个方向的中心(0°)和外围(40°和80°)的垂直和水平纵横比方面,加利福尼亚州。另外,我们比较了后表面图像的放大率(平方比)和对比度的差异。在两种仪器之间的角度视野中未检测到显着差异。长宽比表明,Optos?加利福尼亚的影像比光电二极管更对称?中心200Tx(0.98 vs 0.89,P 0.01)和40°外围(0.93-1.04,△0.11 vs 0.79-1.01,△0.22)和80°外围(0.81-1.25,△0.44 vs 0.42-) 1.12,△0.70)。光电二极管的平方比的幅度是多少?加利福尼亚州在40°外围(1.16-1.28,△0.12比1.06-1.37,△0.31)和80°外围(2.12-2.46,△0.34比1.14-3.29,△2.15)较小。光电的对比?在后极(0.09 vs 0.12,P 0.01),上部(0.07 vs 0.03,P 0.01)和右边缘(0.12 vs 0.07,P 0.01),California图像明显更高。光电?加利福尼亚可以将相等角度的广角图像记录到Optos吗? 200Tx和更对称的图像,在后极,上边缘和右边缘的对比度更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号