Required temporal resolution for accurate thoracic aortic pulse wave velocity measurements by phase-contrast magnetic resonance imaging and comparison with clinical standard applanation tonometry

机译:通过相衬磁共振成像准确测量胸主动脉脉搏波速度所需的时间分辨率,并与临床标准压平眼压计进行比较

获取原文
           

摘要

Background Pulse wave velocity (PWV) is a biomarker for arterial stiffness, clinically assessed by applanation tonometry (AT). Increased use of phase-contrast cardiac magnetic resonance (CMR) imaging allows for PWV assessment with minor routine protocol additions. The aims were to investigate the acquired temporal resolution needed for accurate and precise measurements of CMR-PWV, and develop a tool for CMR-PWV measurements. Methods Computer phantoms were generated for PWV?=?2–20?m/s based on human CMR-PWV data. The PWV measurements were performed in 13 healthy young subjects and 13 patients at risk for cardiovascular disease. The CMR-PWV was measured by through-plane phase-contrast CMR in the ascending aorta and at the diaphragm level. Centre-line aortic distance was determined between flow planes. The AT-PWV was assessed within 2?h after CMR. Three observers (CMR experience: 15, 4, and Results Computer phantoms showed bias 0.27?±?0.32?m/s for a temporal resolution of at least 30?ms. Intraobserver variability for CMR-PWV were: 0?±?0.03?m/s (15?years), -0.04?±?0.33?m/s (4?years), and -0.02?±?0.30?m/s (Conclusions An acquired temporal resolution of at least 30?ms should be used to obtain accurate and precise thoracic aortic phase-contrast CMR-PWV. A new freely available research tool was used to measure PWV in healthy young subjects and in patients, showing low intra- and interobserver variability also for less experienced CMR observers.
机译:背景技术脉搏波速度(PWV)是动脉僵硬度的生物标志物,临床通过压平眼压计(AT)进行评估。相衬心脏磁共振(CMR)成像的使用增多,允许通过少量常规规程添加PWV评估。目的是研究获得准确和精确的CMR-PWV测量所需的时间分辨率,并开发一种用于CMR-PWV测量的工具。方法根据人体CMR-PWV数据生成PWV?=?2-20?m / s的计算机模型。在13名健康的年轻受试者和13名有心血管疾病风险的患者中进行了PWV测量。 CMR-PWV是通过升主动脉和the肌水平处的贯穿平面相差CMR测量的。确定流平面之间的中心线主动脉距离。在CMR后2小时内评估AT-PWV。三名观察员(CMR经验:15、4和结果)计算机幻像显示的偏差为0.27?±?0.32?m / s,时间分辨率至少为30?ms。CMR-PWV的观察者内部变异性为:0?±?0.03? m / s(15?years),-0.04±±0.33?m / s(4?years)和-0.02?±?0.30?m / s(结论应至少获得30?ms的时间分辨率用于获得准确和精确的胸主动脉相差CMR-PWV。一种新的可免费获得的研究工具用于测量健康年轻受试者和患者中的PWV,对于经验不足的CMR观察者,其观察者间和观察者间的变异性也很低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号