首页> 外文期刊>BMC Cardiovascular Disorders >Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography
【24h】

Assessment of tetralogy of Fallot–associated congenital extracardiac vascular anomalies in pediatric patients using low-dose dual-source computed tomography

机译:小剂量双源计算机断层摄影术评估小儿法洛相关先天性心外血管异常的四联症

获取原文
           

摘要

To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). One hundred and twenty-three pediatric patients diagnosed with TOF were included in this retrospective study. All patients underwent DSCT and TTE preoperatively. All associated extracardiac vascular abnormalities and their percentages were recorded. The diagnostic performances of DSCT and TTE were compared based on the surgical results. The image quality of DSCT was rated, and the effective radiation dose (ED) was calculated. A total of 159 associated extracardiac vascular deformities were confirmed by surgery. Patent ductus arteriosus (36, 22.64%), right-sided aortic arch (29, 18.24%), and pulmonary valve stenosis (23, 14.47%) were the most common associated extracardiac vascular abnormalities. DSCT was superior to TTE in demonstrating associated extracardiac anomalies (diagnostic accuracy: 99.13% vs. 97.39%; sensitivity: 92.45% vs. 77.07%; specificity: 99.81% vs. 99.42%). The agreement on grading the image quality of DSCT was excellent (κ?=?0.80), and the mean score of the image quality was 3.39?±?0.50. The mean ED of DSCT was 0.86?±?0.47?mSv. Compared to TTE, low-dose DSCT has high diagnostic accuracy in the depiction of associated extracardiac vascular anomalies in pediatric patients with TOF, and could provide more morphological details for surgeons.
机译:目的探讨双源计算机断层扫描(DSCT)与经胸超声心动图(TTE)相比对小儿法洛(TOF)相关的心外膜血管异常的四联症的诊断价值。这项回顾性研究纳入了被诊断为TOF的123例儿科患者。所有患者术前均接受DSCT和TTE治疗。记录所有相关的心外血管异常及其百分比。根据手术结果比较DSCT和TTE的诊断性能。对DSCT的图像质量进行评级,并计算有效辐射剂量(ED)。手术证实总共有159个相关的心外血管畸形。动脉导管未闭(36,22.64%),右侧主动脉弓(29,18.24%)和肺动脉瓣狭窄(23,14.47%)是最常见的相关心外血管异常。在证实相关的心外膜异常方面,DSCT优于TTE(诊断准确性:99.13%vs. 97.39%;敏感性:92.45%vs. 77.07%;特异性:99.81%vs. 99.42%)。 DSCT的图像质量分级的一致性极好(κ≥0.80),图像质量的平均得分为3.39±0.50。 DSCT的平均ED为0.86≤±0.47≤mSv。与TTE相比,小剂量DSCT在儿科TOF患者相关心外血管异常的描述中具有较高的诊断准确性,并且可以为外科医生提供更多的形态学细节。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号