首页> 外文期刊>BioTechnology: An Indian Journal >A study on determination of best critical value of steps/min in diagnosis exercise intensity for Chinese adolescents by receiver operating characteristic (ROC) curve analysis
【24h】

A study on determination of best critical value of steps/min in diagnosis exercise intensity for Chinese adolescents by receiver operating characteristic (ROC) curve analysis

机译:受试者工作特征曲线分析法确定中国青少年运动强度诊断的每分钟最佳临界值的研究

获取原文
       

摘要

Purpose: This study aims at evaluating the diagnostic value of steps/min in differentiating exercise intensity through Receiver Operating Characteristic (ROC) curve so as to determine the best cutoff point of steps/min for Light Physical Activity (LPA), Moderate Physical Activity (MPA) and vigorous physical activity (VPA) for Chinese children. Method: With the synchronous monitor of the portable gas metabolic analyzer (Cosmed K4b2) and three-axis accelerometer (ActiGraph GT3X), 60 subjects of 11-14 years old middle school students (being evenly composed of males and females) would be tested with resting and 3~8km/h walking/running exercises. The experimental data were used to draw a ROC curve. Result: The result showed that there was no gender difference (P>0.05) between males and females on steps/min and exercise intensity when they conducted the same activity; the corresponding AUC of 3METs and 6METs was 0.906(P<0.05) and 0.895(P<0.05) respectively, which manifested that steps/min had great value to diagnose the exercise intensity. The best critical point of steps/min for 3METs and 6METs determined by the maximum Youden value was 121 steps/min and144 steps/min respectively with high sensitivity (0.744~0.944) and low 1-specificity (0.035~0.160). Steps/min was effective to differentiate the best critical point of exercise intensity, and the consistency examination result was also good. Conclusion: It can be concluded from this study that steps/min is effective to diagnose the exercise intensity and the best critical value of steps/min for the adolescents to do MPA is 121 steps/min to 144 steps/min and ≥144 steps/min for VPA.
机译:目的:本研究旨在通过接收器工作特性(ROC)曲线评估步/分对运动强度的诊断价值,从而确定轻度运动(LPA),中度运动( MPA)和针对中国儿童的剧烈运动(VPA)。方法:使用便携式气体代谢分析仪(Cosmed K4b2)和三轴加速度计(ActiGraph GT3X)的同步监视器,对11-14岁中学生(男女均分)的60名受试者进行测试。休息和3〜8 km / h的步行/跑步锻炼。实验数据用于绘制ROC曲线。结果:结果表明,进行相同运动时,男女在步数/分钟和运动强度上没有性别差异(P> 0.05); 3METs和6METs的相应AUC分别为0.906(P <0.05)和0.895(P <0.05),表明steps / min对运动强度的诊断具有重要价值。由最大Youden值确定的3METs和6METs的最佳临界点/分分别为121步/分和144步/分,灵敏度高(0.744〜0.944)和低1-特异性(0.035〜0.160)。每分钟步数可以有效区分运动强度的最佳临界点,一致性检查结果也很好。结论:从这项研究可以得出结论,步数/分钟可以有效地诊断运动强度,并且青少年进行MPA的步数/分钟的最佳临界值为121步数/分钟至144步数/分钟且≥144步数/ VPA的最小值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号