首页> 外文期刊>Desalination >Silica fouling revisited
【24h】

Silica fouling revisited

机译:再谈二氧化硅结垢

获取原文
获取原文并翻译 | 示例

摘要

The potential for silica scale formation in reverse osmosis (RO) systems is thought to limit recovery in many installations, which may unnecessarily increase costs. In the past, the standard industry design guideline has been to limit the maximum silica concentration to about 120 mg/l in the concentrate at 25℃ (77℉) based on solubility data, such as ASTM D4993-89, and operational problems observed at field sites. However, data reported in this paper indicate that the nominal 120 mg/l silica limit can be significantly exceeded in many cases, but that silica scaling could occur at lower concentrations in other cases. The effect of variables, such as the presence of iron or other heavy metals, are discussed.
机译:人们认为在反渗透(RO)系统中形成氧化硅垢的可能性会限制许多装置的回收,这可能会不必要地增加成本。过去,根据溶解度数据(例如ASTM D4993-89)和在操作条件下观察到的操作问题,标准的工业设计指南一直将25℃(77℉)下浓缩物中的最大二氧化硅浓度限制为约120 mg / l。现场。但是,本文报道的数据表明,在许多情况下可以大大超过标称的120 mg / l二氧化硅极限,但在其他情况下,在较低浓度下也可能发生二氧化硅水垢。讨论了变量的影响,例如铁或其他重金属的存在。