首页> 外文期刊>Dental materials >Effects of the acetone content of single solution dentin bonding agents on the adhesive layer thickness and the microtensile bond strength
【24h】

Effects of the acetone content of single solution dentin bonding agents on the adhesive layer thickness and the microtensile bond strength

机译:单溶液牙本质粘合剂中丙酮含量对粘合剂层厚度和微拉伸强度的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. This study investigated the hypothesis that varying the acetone content of single solution dentin bonding agents may affect the adhesive layer thickness and microtensile bond strength (MTBS) of the bonded complex, and explored whether the adhesive layer thickness is a valid predictor for MTBS. Methods. Experimental dentin bonding agents containing (27, 37, 47, 57, or 67) mass fraction% acetone were used to bond composite resin onto occlusal dentin surfaces of extracted human molars. The adhesive layer thickness was determined by digitized image analysis. MTBS was measured after 48 h. The fracture surfaces were observed using SEM. Results. With increasing acetone content, MTBS varied from 38 MPa (67% acetone) to the highest MTBS of 64 MPa (37% acetone), while the adhesive layer thickness decreased linearly. Both dependent variables demonstrated moderate inverse correlation with the acetone content (p < 0.0001), but were not correlated with each other (p > 0.05). Ninety-four percent of the specimens showed fractures within the adhesive layer extending toward the interfaces with the hybrid layer or the composite resin. In the groups containing 57 and 67% acetone, cracks were observed at these interfaces. Significance. Rather than the adhesive layer thickness, interfacial cracks in specimens with acetone-rich bonding agents may have caused lower MTBS. Within the scope of this investigation, lower acetone concentrations, as could be anticipated from solvent evaporation during clinical use of the bonding agent, did not seem to lower MTBS, but rather improved the integrity of the dentin/adhesive bond. Published by Elsevier Ltd. on behalf of Academy of Dental Materials.
机译:目标。这项研究调查了以下假设:改变单一溶液牙本质粘合剂的丙酮含量可能会影响粘合复合物的粘合剂层厚度和微拉伸粘合强度(MTBS),并探讨了粘合剂层厚度是否是MTBS的有效预测指标。方法。使用含有(27、37、47、57或67)质量分数%丙酮的实验性牙本质粘合剂将复合树脂粘合到提取的人类臼齿的咬合牙本质表面上。粘合剂层的厚度通过数字化图像分析确定。 48小时后测量MTBS。使用SEM观察断裂面。结果。随着丙酮含量的增加,MTBS从38 MPa(67%丙酮)变化到最高MTBS 64 MPa(37%丙酮),而粘合剂层的厚度线性减小。两个因变量均显示出与丙酮含量适度的逆相关性(p <0.0001),但彼此之间不相关(p> 0.05)。 94%的样品显示出粘合剂层内的裂缝向与混合层或复合树脂的界面延伸。在含57%和67%丙酮的组中,在这些界面处观察到裂纹。意义。使用富含丙酮的粘合剂的样品中的界面裂纹可能会导致MTBS降低,而不是粘合剂层的厚度。在该研究范围内,较低的丙酮浓度(似乎可以降低粘合剂的MTBS),但可以改善牙本质/胶粘剂的完整性,而丙酮浓度的降低似乎并未降低MTBS,而是降低了MTBS的浓度。由Elsevier Ltd.代表牙科材料学院出版。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号