首页> 外文期刊>Dental materials >Polymerization stress, shrinkage and elastic modulus of current low-shrinkage restorative composites
【24h】

Polymerization stress, shrinkage and elastic modulus of current low-shrinkage restorative composites

机译:当前低收缩率恢复性复合材料的聚合应力,收缩率和弹性模量

获取原文
获取原文并翻译 | 示例
       

摘要

Objective. To compare currently available low-shrinkage composites with others regarding polymerization stress, volumetric shrinkage (total and post-gel), shrinkage rate and elastic modulus. Methods. Seven BisGMA-based composites (Durafill/DU, Filtek Z250/FZ, Heliomolar/HM, Aelite LS Posterior/AP, Point 4/P4, Filtek Supreme/SU, ELS/EL), a silorane-based (Filtek LS, LS), a urethane-based (Venus Diamond, VD) and one based on a dimethacrylate-derivative of dimer acid (N'Durance, ND) were tested. Polymerization stress was determined in 1-mm high specimens inserted between two PMMA rods attached to a universal testing machine. Total volumetric shrinkage was measured using a mercury dilatometer. Maximum shrinkage rate was used as a parameter of the reaction speed. Post-gel shrinkage was measured using strain-gages. Elastic modulus was obtained by three-point bending. Data were submitted to one-way ANOVA/Tukey test (p = 0.05), except for elastic modulus (Kruskal-Wallis). Results. Composites ranked differently for total and post-gel shrinkage. Among the materials considered as "low-shrinkage" by the respective manufacturers, LS, EL and VD presented low post-gel shrinkage, while AP and ND presented relatively high values. Polymerization stress showed a strong correlation with post-gel shrinkage except for LS, which presented high stress. Elastic modulus and shrinkage rate showed weak relationships with polymerization stress. Significance. Not all low-shrinkage composites demonstrated reduced polymerization shrinkage. Also, in order to effectively reduce polymerization stress, a low post-gel shrinkage must be associated to a relatively low elastic modulus.
机译:目的。在聚合应力,体积收缩率(总和后凝胶),收缩率和弹性模量方面,将目前可用的低收缩率复合材料与其他材料进行比较。方法。七种基于BisGMA的复合材料(Durafill / DU,Filtek Z250 / FZ,Heliomolar / HM,Aelite LS后牙/ AP,Point 4 / P4,Filtek Supreme / SU,ELS / EL),基于硅氧烷的复合材料(Filtek LS,LS)分别测试了基于氨基甲酸酯的(Venus Diamond,VD)和基于二甲基丙烯酸的二甲基丙烯酸酯衍生物(N'Durance,ND)。在插入通用试验机的两个PMMA棒之间插入的1-mm高样品中确定聚合应力。使用水银膨胀仪测量总体积收缩率。最大收缩率用作反应速度的参数。凝胶后收缩使用应变计测量。通过三点弯曲获得弹性模量。除弹性模量(Kruskal-Wallis)外,其他数据均经过单向ANOVA / Tukey检验(p = 0.05)。结果。复合材料在总收缩率和后凝胶收缩率上的排名不同。在各自制造商认为“低收缩”的材料中,LS,EL和VD的凝胶后收缩率低,而AP和ND的值较高。聚合应力与凝胶后收缩密切相关,除了LS表现出高应力外。弹性模量和收缩率与聚合应力之间的关系较弱。意义。并非所有的低收缩率复合材料都显示出降低的聚合收缩率。而且,为了有效地降低聚合应力,低的凝胶后收缩必须与相对较低的弹性模量相关联。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号