首页> 外文期刊>Dental materials >Accuracy of Kubelka-Munk reflectance theory for dental resin composite material
【24h】

Accuracy of Kubelka-Munk reflectance theory for dental resin composite material

机译:牙科树脂复合材料的Kubelka-Munk反射理论的准确性

获取原文
获取原文并翻译 | 示例
       

摘要

Objective. The objective of this study is to determine the effect of interfacial reflection correction (IRC) on the accuracy of this reflectance model for contemporary denta. resin composite materials. Methods. Visible reflectance spectra were obtained for varying thicknesses (~0.3-1.2mm) of five shades of each of two brands (Herculite Ultra and Kalore) of dental resin composite materials on black, gray and white backings. For each shade and brand, K-M theory was fit (SAS non-linear fit) for each of three IRC methods: (1) no IRC (No), (2) an IRC method which uses a theoretical value of the internal reflection for translucent materials (Tr), and (3) an IRC method which uses a derived value of the internal reflection for opaque materials (Op). The errors were subjected to repeated measures analysis of variance and Bonferroni corrections were applied to selected pairwise comparisons. Results. The Op method had a statistically lower error than the No method at wavelengths from 460 to 560 nm, and the Tr method had this lower error at wavelengths from 440 to 780 nm. Signi/icance. Corrected K-M reflectance theory may be used to accurately quantify the optical K-M absorption and scattering coefficients for contemporary dental resin composite materials, and this theory may be used to calculate accurately the reflectance spectrum for a clinically relevant thickness value and for a backing that is low, mid-range or high in lightness. Both color and translucency information of resin composite materials may be accurately predicted using corrected Kubelka-Munk reflectance model.
机译:目的。本研究的目的是确定界面反射校正(IRC)对当代牙本质反射模型准确性的影响。树脂复合材料。方法。在黑色,灰色和白色背衬上,牙科树脂复合材料的两个品牌(Herculite Ultra和Kalore)的五个品牌的五个阴影的厚度变化(约0.3-1.2mm)时,获得了可见的反射光谱。对于每种阴影和品牌,对于三种IRC方法中的每一种,均适用KM理论(SAS非线性拟合):(1)无IRC(否),(2)一种使用内部反射理论值半透明的IRC方法材料(Tr),以及(3)IRC方法,该方法使用不透明材料(Op)的内部反射值。对误差进行方差的重复测量分析,并将Bonferroni校正应用于选定的成对比较。结果。在460至560 nm的波长处,Op方法的统计误差要比No方法低,而在440至780 nm的波长处,Tr方法的误差要低。重要性/意义。校正后的KM反射率理论可用于精确量化当代牙科树脂复合材料的光学KM吸收和散射系数,并且该理论可用于精确计算临床相关厚度值和低背衬的反射光谱,中档或高亮度。使用校正的Kubelka-Munk反射率模型可以准确预测树脂复合材料的颜色和半透明信息。

著录项

  • 来源
    《Dental materials》 |2012年第7期|729-735|共7页
  • 作者单位

    Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, OH, USA;

    Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, OH, USA;

    Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, 305 West 12th Avenue, Columbus, OH 43210-1267, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    reflectance theory; accuracy; interfacial reflection corrections; nanohybrid dental resin composites;

    机译:反射率理论准确性;界面反射校正;纳米混合牙科树脂复合材料;
  • 入库时间 2022-08-18 03:47:08

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号