Objectives. Clinical experience with implant-supported dentures indicates that fracture and chipping of teeth are becoming an issue. Tooth fracture and chipping rates of approximately 2.5% per year are being experienced at one university. There has been no standardized test developed for bulk fracture or chipping of denture teeth. Such a test would aid in the development of improved teeth and in their evaluation. Methods. Central incisor teeth were embedded in acrylic and loaded on incisal edges at 90 to their long axes. Teeth tested included ones commercially available and two sets made from improved materials designed to increase toughness. Cyclic loading was done at 5 Hz from 20 N to 135 N, 150 N, 175 N and 200 N. Data was analyzed using lifetime analysis software fit at each of the accelerated loads and then extrapolated to clinical use loads (Alta 7, Reliasoft Corp.) Clinical use loads were derived from extrapolation of probability of failure (Pf) data to 2.5% Pf. Results. When carefully embedded, teeth could be reproducibly loaded to failure by bulk fracture involving a failure mode similar to that seen clinically. Clinical use loads were calculated to be in the range of 70 N. Results from accelerated loading could be fit to similar probability of failure distributions allowing extrapolation to clinical use loads. Significance. This work was able to develop a clinically valid bulk fracture test for the fatigue failure of incisor denture teeth. It appears that teeth fabricated with improved materials will be expected to perform better clinically. Thus both the null hypotheses were rejected.
机译:目标。植入物支持的假牙的临床经验表明,牙齿的破裂和碎裂成为一个问题。在一所大学中,每年发生的牙齿断裂和崩裂率约为2.5%。还没有针对义齿的整体断裂或崩裂制定标准测试。这样的测试将有助于改进牙齿的发展并对其进行评估。方法。将中切牙嵌入丙烯酸树脂中,并在切缘上沿长轴90度加载。被测试的牙齿包括市售的牙齿和两套由旨在提高韧性的改良材料制成的牙齿。在20 Hz至135 N,150 N,175 N和200 N的5 Hz下进行循环加载。使用适合每个加速负载的寿命分析软件分析数据,然后推断到临床使用负载(Alta 7,Reliasoft Corp 。)临床使用负荷是从失败概率(Pf)数据外推到2.5%Pf得出的。结果。当仔细地嵌入牙齿后,可通过涉及与临床上相似的破坏模式的整体骨折将牙齿重现性地破坏。经计算,临床使用负荷在70 N范围内。加速负荷的结果可能适合类似的故障分布概率,从而可以推断出临床使用负荷。意义。这项工作能够为门牙义齿的疲劳破坏开发出临床上有效的整体断裂试验。看来用改良材料制成的牙齿有望在临床上表现更好。因此,两个原假设都被拒绝了。

著录项

  • 来源
    《Dental materials》 |2013年第10期|1012-1019|共8页
  • 作者单位

    University of Applied Sciences Muenster, Faculty of Engineering Physics, Stegerwaldstr. 39, D-48565 Steinfurt, Germany;

    Department of Reconstructive Sciences, Uniuersity of Connecticut Health Center, Farmington, CT, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Denture teeth; Bulk fracture; Cyclic fatigue; Implant prostheses; Accelerated testing;