...
首页> 外文期刊>Cytometry Part B: Clinical Cytometry >New BD FACSCountTM CD4 reagent system for simultaneous enumeration of percent and absolute CD4 T-lymphocytes in HIV-1-infected pediatric patients
【24h】

New BD FACSCountTM CD4 reagent system for simultaneous enumeration of percent and absolute CD4 T-lymphocytes in HIV-1-infected pediatric patients

机译:新型BD FACSCount TM CD4试剂系统,用于同时计数HIV-1感染的小儿患者的CD4 T细胞百分比和绝对值

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BackgroundAbsolute CD4+ T-lymphocyte counts are used in the initiation and monitoring of antiretroviral therapy in HIV-infected patients. Becton Dickinson's (BD) FACSCountTM system was introduced 12 years ago as a dedicated instrument for enumeration of absolute CD4+ T-lymphocytes. However, this system does not provide percent CD4+ T-lymphocyte that is the required monitoring parameter in pediatric patients. We evaluated a new BD FACSCount CD4 software and reagents for simultaneous percent and absolute CD4+ T-lymphocytes in HIV-infected blood.MethodsPercent and absolute CD4+ T-lymphocytes in 149 HIV-infected blood samples were determined using a new FACSCount system. Results of percent and absolute CD4+ T-lymphocytes were compared between the dual-platform (DP) method, using BD FACScanTM flow cytometer plus hematology analyzer and the standard FACSCount system. Correlation and agreement were analyzed using linear regression and Bland-Altman analysis.ResultsPercent CD4+ T-lymphocyte values obtained from the new FACSCount system correlated well with DP FACScan method (r2 = 0.977, P < 0.0001). Mean bias was only -0.36% [limit of agreement (LOA): -2.52% to +1.80%] and percent similarity was 101.36%. For absolute CD4+ T-lymphocyte, the new system correlated highly with standard FACSCount system (r2 = 0.986, P < 0.0001), with a percent similarity of 98.2. Mean bias was +3.39 cells/l with LOA of -52.53 cells/l to +59.31 cells/l.ConclusionThis new FACSCount system is a simple and reliable system for enumeration of absolute and percent CD4+ T-lymphocytes. Having one system giving both results should reduce the cost and thus increase access to CD4 testing for pediatric and adult patients. © 2008 Clinical Cytometry Society
机译:背景绝对CD4 + T淋巴细胞计数用于HIV感染患者的抗逆转录病毒疗法的启动和监测。 Becton Dickinson(BD)FACSCountTM系统是12年前推出的,它是用于枚举绝对CD4 + T淋巴细胞的专用仪器。但是,该系统无法提供CD4 + T淋巴细胞百分比,这是儿科患者所需的监测参数。我们评估了一种新的BD FACSCount CD4软件和试剂,用于检测HIV感染的血液中同时存在的百分比和绝对CD4 + T淋巴细胞。方法使用新的FACSCount系统确定149个HIV感染的血液样本中的百分比和绝对CD4 + T淋巴细胞。使用BD FACScanTM流式细胞仪加血液分析仪和标准FACSCount系统,在双平台(DP)方法之间比较了百分比和绝对CD4 + T淋巴细胞的结果。使用线性回归和Bland-Altman分析来分析相关性和一致性。结果从新FACSCount系统获得的CD4 + T淋巴细胞百分率与DP FACScan方法相关性很好(r2 = 0.977,P <0.0001)。平均偏差仅为-0.36%[协议限制(LOA):-2.52%至+ 1.80%],相似性百分比为101.36%。对于绝对CD4 + T淋巴细胞,新系统与标准FACSCount系统高度相关(r2 = 0.986,P <0.0001),相似性百分比为98.2。平均偏倚为+3.39细胞/ l,LOA为-52.53细胞/ l至+59.31细胞/ l。结论这一新的FACSCount系统是一种简单可靠的系统,用于枚举绝对和百分比CD4 + T淋巴细胞。拥有一个同时给出两种结果的系统可以降低成本,从而增加儿童和成人患者CD4检测的机会。 ©2008临床细胞计数协会

著录项

  • 来源
    《Cytometry Part B: Clinical Cytometry》 |2008年第s1期|98-106|共9页
  • 作者单位

    Center of Excellence for Flow Cytometry, Office for Research and Development, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand|Department of Immunology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand;

    Center of Excellence for Flow Cytometry, Office for Research and Development, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand;

    Center of Excellence for Flow Cytometry, Office for Research and Development, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand;

    Department of Immunology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号