首页> 外文期刊>Construction and Building Materials >Experimental investigation of composite beams reinforced with GFRP I-beam and steel bars
【24h】

Experimental investigation of composite beams reinforced with GFRP I-beam and steel bars

机译:GFRP工字钢加钢筋组合梁的试验研究

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents results of an experimental study on the flexural behaviour of a composite beam, which is reinforced with longitudinal tensile steel bars as well as glass fibre reinforced polymer (GFRP) pultruded I-beam encased in concrete. Five beam specimens, including one traditional reinforced concrete (RC) beam and four composite beams, were cast and tested under four-point bending. The variables involved in the composite beams include the type of longitudinal tensile bars (steel bars and GFRP bars) and the location of the I-beam in the cross-section (middle and a shift of 30 mm towards the tension region). The test results presented in this study show that the proposed composite beams have a very ductile response due to the existence of the tensile steel bars, and the yield point of the composite beam is controlled by the tensile steel bars. The ultimate load of the proposed composite beam in this study is higher than the traditional RC beam in this study, and the ultimate load is governed by the encased I-beam. When GFRP bars were used to replace the tensile steel bars to reinforce the composite beams, the brittle failure of GFRP bars caused lack of ductility of the beam members, and both the stiffness and ultimate load were reduced significantly. Compared with steel bars, the slip between the concrete and the I-beam was also increased when GFRP bars were used. The different location of the I-beam has little effect on the flexural response. (C) 2017 Elsevier Ltd. All rights reserved.
机译:本文介绍了对复合梁的抗弯性能进行实验研究的结果,该复合梁由纵向抗拉钢筋以及玻璃纤维增​​强聚合物(GFRP)拉挤在混凝土中的工字梁增强。铸造了五个梁试件,包括一个传统的钢筋混凝土(RC)梁和四个复合梁,并在四点弯曲下进行了测试。组合梁中涉及的变量包括纵向拉伸钢筋的类型(钢筋和GFRP钢筋)和工字梁在横截面中的位置(中间和向拉伸区域移动30 mm)。这项研究给出的测试结果表明,由于存在抗拉钢筋,所提出的复合梁具有非常好的延性响应,并且复合梁的屈服点由抗拉钢筋控制。本研究中建议的组合梁的极限载荷高于本研究中的传统RC梁,并且极限载荷由包裹的工字梁控制。当使用GFRP钢筋代替拉伸钢筋来增强复合材料梁时,GFRP钢筋的脆性破坏导致梁构件的延展性不足,并且刚度和极限载荷均显着降低。与钢筋相比,使用GFRP钢筋时,混凝土和工字梁之间的滑动也增加了。工字梁的不同位置对挠曲响应影响很小。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号