首页> 外文期刊>Construction and Building Materials >Time-dependent corrosion process and non-uniform corrosion of reinforcement in RC flexural members in a tidal environment
【24h】

Time-dependent corrosion process and non-uniform corrosion of reinforcement in RC flexural members in a tidal environment

机译:潮汐环境下钢筋混凝土受弯构件中随时间变化的腐蚀过程和钢筋的非均匀腐蚀

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this paper, the time-dependent corrosion of tensile reinforcements in RC beams with two water-to-cement (W/C) ratios under flexural load is studied, based on the accelerated chloride penetration tests within 400 d exposure time. The mass and volume corrosion rates of tensile reinforcements were obtained by the weighing method and three-dimensional (3D) laser scanning technique, respectively. Moreover, the 3D laser measurement data was used to determine the distribution of residual cross-sectional areas of corroded tensile reinforcements along reinforcement length and analyze the non uniformity of corroded tensile reinforcements. Then, a prediction model of maximum area of corrosion of tensile reinforcements was determined. The feasibility of prediction model was certified by comparing the predicted values with measured values obtained by the 3D laser scanning technique. Results indicate that the mass corrosion rate of tensile reinforcements has an obvious time dependence. After about 320 d exposure time, the mass corrosion rates of tensile reinforcements increase rapidly with exposure time. Comparing with the mass corrosion rates, the volume corrosion rates can also be taken as another measurement indicator of uniform corrosion rates. Moreover, with the increasing of W/C ratio, exposure time and flexural load, the corrosion non-uniformity of tensile reinforcements along reinforcement length increases in different degrees, and flexural load has the greatest influence on the corrosion non uniformity. In addition, under the different W/C ratios, exposure times and flexural loads, consistent change trends of predicted and measured maximum area of corrosion can be observed. Among them, the predicted maximum area of corrosion without flexural loads is more close to the measured value. (C) 2019 Elsevier Ltd. All rights reserved.
机译:本文基于在400 d暴露时间内加速的氯离子渗透试验,研究了在挠曲载荷下具有两种水灰比(W / C)的RC梁中抗拉钢筋的时间依赖性腐蚀。拉伸增强材料的质量和体积腐蚀速率分别通过称量法和三维(3D)激光扫描技术获得。此外,使用3D激光测量数据来确定腐蚀后的拉伸钢筋沿横截面长度的剩余横截面的分布,并分析腐蚀后的拉伸钢筋的不均匀性。然后,确定了抗拉钢筋最大腐蚀面积的预测模型。通过将预测值与通过3D激光扫描技术获得的测量值进行比较,证明了预测模型的可行性。结果表明,抗拉钢筋的质量腐蚀速率具有明显的时间依赖性。在约320 d的暴露时间后,拉伸增强材料的质量腐蚀速率随暴露时间而迅速增加。与质量腐蚀速率相比,体积腐蚀速率也可以作为均匀腐蚀速率的另一个测量指标。而且,随着W / C比,暴露时间和弯曲载荷的增加,抗拉钢筋沿钢筋长度方向的腐蚀不均匀性不同程度地增加,弯曲载荷对腐蚀不均匀性的影响最大。另外,在不同的W / C比,暴露时间和挠曲载荷下,可以观察到预测和测量的最大腐蚀面积的一致变化趋势。其中,没有弯曲载荷的预计最大腐蚀面积更接近测量值。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Construction and Building Materials》 |2019年第20期|79-90|共12页
  • 作者单位

    Zhejiang Univ Technol, Coll Civil Engn & Architecture, Hangzhou 310014, Zhejiang, Peoples R China;

    Zhejiang Univ Technol, Coll Civil Engn & Architecture, Hangzhou 310014, Zhejiang, Peoples R China;

    Zhejiang Univ Technol, Coll Civil Engn & Architecture, Hangzhou 310014, Zhejiang, Peoples R China|Key Lab Civil Engn Struct & Disaster Prevent & Mi, Hangzhou 310014, Zhejiang, Peoples R China;

    Zhejiang Univ Technol, Coll Civil Engn & Architecture, Hangzhou 310014, Zhejiang, Peoples R China;

    Zhejiang Univ Technol, Coll Civil Engn & Architecture, Hangzhou 310014, Zhejiang, Peoples R China;

    Zhejiang Univ Technol, Coll Civil Engn & Architecture, Hangzhou 310014, Zhejiang, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Tidal environment; RC members; Flexural loads; Time-dependent reinforcement corrosion; Non-uniform corrosion;

    机译:潮汐环境;RC构件;弯曲荷载;时变钢筋腐蚀;非均匀腐蚀;