Mixed 4-node elements based on the Hu-Washizu (HW) functional are developed for the representation of the assumed strain in the natural basis at the element's center, i.e. for the contravariant transformation rule. In other aspects, the formulation is identical as in our previous paper [9], to which this note is an addendum.rnTwo mixed HW elements based on the 5-parameter stress are developed; they use either the 7-parameter or 9-parameter strain representation. The stress and strain representations are assumed in terms of skew coordinates, see [10]. The numerical tests involving coarse distorted meshes are used to assess the effects of using the contravariant strain representation.rnThe tests show that both elements pass the discrete inf-sup test. Accuracy of the element based on the 9-parameter strain, designated as HW14-S and selected as the best in [9], remains unaffected. Accuracy of the element based on the 7-parameter strain is significantly improved.
机译:开发了基于Hu-Washizu(HW)函数的混合4节点单元,用于在单元中心以自然基础表示假定应变,即用于逆变换规则。在其他方面,该公式与我们先前的论文[9]相同,在此之前为附录。rn开发了两个基于5参数应力的混合HW元素。他们使用7参数或9参数应变表示。应力和应变表示是根据偏斜坐标假设的,请参见[10]。使用涉及粗变形网格的数值测试来评估使用反应变表示法的效果。rn测试表明,这两个元素都通过了离散的insup测试。基于9参数应变的元素精度(在[9]中被指定为HW14-S,被选为最佳)仍不受影响。基于7参数应变的元素精度显着提高。