This paper investigates the effect of fire on the performance of geosynthetic reinforced soil bridge abutments using experimental tests and finite element analyses. Experimental programs were comprised of a series of tensile strength tests at elevated temperatures and fire resistance tests, which were performed on a physical model. Findings revealed the adverse effect of fire on geosynthetic reinforced soil bridge abutments when fire duration exceeded 60 min. Results show that the depth within the backfill affected by the fire is approximately 50 cm. (C) 2016 Elsevier Ltd. All rights reserved.
机译:本文通过实验测试和有限元分析,研究了火灾对土工加筋土桥基台性能的影响。实验程序包括一系列在物理模型上进行的高温拉伸强度测试和耐火性测试。研究结果表明,当火灾持续时间超过60分钟时,火灾对土工合成材料土桥桥台的不利影响。结果表明,受火影响的回填深度约为50厘米。 (C)2016 Elsevier Ltd.保留所有权利。