首页> 外文期刊>Chinese Optics Letters >A novel radiant source for infrared calibration by using a grooved surface
【24h】

A novel radiant source for infrared calibration by using a grooved surface

机译:一种新型的辐射源,通过使用带凹槽的表面进行红外校准

获取原文
获取原文并翻译 | 示例

摘要

A radiant source with a large aperture at 5-95℃ in the wavelength bands of 8-12 μm for calibrating infrared imaging systems has been designed. The effective emissivity of its flat bottom with concentric Ⅴ-grooves was evaluated by the Monte-Carlo method whose correctness was tested and accuracy was discussed. The structure of the source was completed by incorporating the simulation results with the blackbody cavity effect. The source was certificated via an optical measurement system. The source can provide a consistent radiant flux with temperature uniformity of ±0.1℃ over an area of diameter of φ80 mm.
机译:设计了一种在5-95℃波长范围为8-12μm的大孔径辐射源,用于校准红外成像系统。采用蒙特卡罗方法对同心Ⅴ型槽的平底有效发射率进行了评估,并测试了其正确性并讨论了精度。通过将模拟结果与黑体腔效应相结合,完成了源的结构。光源通过光学测量系统认证。该辐射源可在直径φ80mm的区域内提供一致的辐射通量,温度均匀度为±0.1℃。