Row characteristics in the entrance of plate-fin heat exchanger have been investigated by means of particle image velocimetry (PIV). The flow field was measured using the two-frame cross-correlation technique. Streamline and velocity contour graphs at different cross-sections were obtained in the experiment. The experimental results indicate that flow maldistribution in the conventional header is very serious, while the improved header configuration with punched baffle can effectively improve the uniformity. The flow maldistribution parameter in plate-fin heat exchanger has been reduced from 1.21 to 0.21, and the ratio of the maximum velocity to the minimum is reduced from 23.2 to 1.8 by installing the punched baffle. The results suggest room for the optimum design of plate-fin heat exchanger.
机译:板翅式换热器入口处的行特性已通过粒子图像测速法(PIV)进行了研究。使用两帧互相关技术测量流场。在实验中获得了不同横截面的流线和速度等高线图。实验结果表明,常规集管中的流量分布不均非常严重,而改进的带有穿孔挡板的集管配置可以有效地改善均匀性。通过安装穿孔挡板,板翅式换热器中的流量分配不均参数从1.21降低到0.21,最大速度与最小速度之比从23.2降低到1.8。结果为板翅式换热器的优化设计提供了空间。