首页> 外文期刊>Chinese Journal of Astronomy and Astrophysics >The OH Maser Line Receiving System for the Urumqi 25m Radio Telescope
【24h】

The OH Maser Line Receiving System for the Urumqi 25m Radio Telescope

机译:乌鲁木齐25m射电望远镜的OH Maser线接收系统

获取原文
获取原文并翻译 | 示例
       

摘要

A maser spectral line system is newly implemented on the Urumqi 25m Radio Telescope. The system consists mainly of a cooling receiver and a 4096 channels digital correlation spectrometer. The frequency resolution of the spectrometer at the maximum signal bandwidth of 80 MHz is 19.5 kHz. After careful calibrations observation at the 1665 MHz OH maser emission was made towards a number of sources, including W49N and W75N. The observed results demonstrate that the digital correlation spectrometer is suitable for astronomical spectral line observations.
机译:在乌鲁木齐25m射电望远镜上新实施了maser谱线系统。该系统主要由一个冷却接收器和一个4096通道数字相关光谱仪组成。在最大信号带宽为80 MHz时,光谱仪的频率分辨率为19.5 kHz。经过仔细的校准后,在1665 MHz处对包括W49N和W75N在内的许多辐射源进行了OH maser发射。观测结果表明,数字相关光谱仪适用于天文光谱线观测。