首页> 外文期刊>Chest >Comparison of the SpO2/FIO2 Ratio and the PaO2/FIO2 Ratio in Patients With Acute Lung Injury or ARDS
【24h】

Comparison of the SpO2/FIO2 Ratio and the PaO2/FIO2 Ratio in Patients With Acute Lung Injury or ARDS

机译:急性肺损伤或ARDS患者的SpO2 / FIO2比和PaO2 / FIO2比的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The diagnostic criteria for acute lung injury (ALI) and ARDS utilize the PaO2fraction of inspired oxygen (FIO2) [P/F] ratio measured by arterial blood gas analysis to assess thendegree of hypoxemia. We hypothesized that the pulse oximetric saturation (SpO2)/FIO2 (S/F) rationcan be substituted for the P/F ratio in assessing the oxygenation criterion of ALI.nMethods: Corresponding measurements of SpO2 (values < 97%) and PaO2 from patients enrollednin the ARDS Network trial of a lower tidal volume ventilator strategy (n u0001 672) were comparednto determine the relationship between S/F and P/F. S/F threshold values correlating with P/Fnratios of 200 (ARDS) and 300 (ALI) were determined. Similar measurements from patientsnenrolled in the ARDS Network trial of lower vs higher positive end-expiratory pressure (n u0001 402)nwere utilized for validation.nResults: In the derivation data set (2,613 measurements), the relationship between S/F and P/Fnwas described by the following equation: S/F u0001 64 u0002 0.84 u0003 (P/F) [p < 0.0001; r u0001 0.89). An S/Fnratio of 235 corresponded with a P/F ratio of 200, while an S/F ratio of 315 corresponded with anP/F ratio of 300. The validation database (2,031 measurements) produced a similar linearnrelationship. The S/F ratio threshold values of 235 and 315 resulted in 85% sensitivity with 85%nspecificity and 91% sensitivity with 56% specificity, respectively, for P/F ratios of 200 and 300.nConclusion: S/F ratios correlate with P/F ratios. S/F ratios of 235 and 315 correlate with P/F ratiosnof 200 and 300, respectively, for diagnosing and following up patients with ALI and ARDS.
机译:背景:急性肺损伤(ALI)和ARDS的诊断标准利用动脉血气分析测量的PaO2 /吸入氧分数(FIO2)[P / F]比来评估低氧血症的程度。我们假设在评估ALI的氧合标准时,可以用脉搏血氧饱和度(SpO2)/ FIO2(S / F)比率代替P / F比值.n方法:对患者的SpO2(值<97%)和PaO2进行相应测量比较低潮气量呼吸机策略(编号u0001 672)在ARDS网络试验中的参与度,以确定S / F与P / F之间的关系。确定与P / Fnratios 200(ARDS)和300(ALI)相关的S / F阈值。通过使用ARDS网络试验中较低或较高的呼气末正压(n u0001 402)患者的相似测量值进行验证。n结果:在派生数据集中(2,613个测量值),S / F与P / Fn之间的关系用以下等式描述:S / F u0001 64 u0002 0.84 u0003(P / F)[p <0.0001; r u0001 0.89)。 S / Fratio 235对应于200的P / F比,而S / F比315对应于P / F的300。验证数据库(2,031个测量值)产生了相似的线性关系。 S / F比阈值235和315分别导致200/300的P / F比值的灵敏度为85%,n特异性为91%,灵敏度为91%,特异性为56%.n结论:S / F比值与P相关/ F比。用于诊断和随访ALI和ARDS的患者的S / F比235和315分别与200和300的P / F比n相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号