首页> 外文期刊>Chemie Ingenieur Technik >Estimation of Chromatographic Columns Performances using Computer Tomography and CFD Simulations
【24h】

Estimation of Chromatographic Columns Performances using Computer Tomography and CFD Simulations

机译:使用计算机断层扫描和CFD模拟估算色谱柱性能

获取原文
获取原文并翻译 | 示例
           

摘要

The flow inside a chromatographic column depends decisively on the packed bed inside. Non-destructive X-ray computed tomography (CT) was applied as a novel measurement technique to visualize the distribution of velocity and axial dispersion coefficients in preparative scale columns. The results show, that spherical particles seem to be more efficient than irregular ones in terms of HETP, which has to be partly a result of the more homogeneous flow profile they induce. The prediction of column performance in dependence of the structure of the packed bed was simulated by CFD (Computational Fluid Dynamics), using a model which besides the hydrodynamics parameters attained by CT also includes adsorption isotherms and mass transfer parameters. The results of the CFD simulation shall help to establish rules for selecting the right adsorption material for a given separation task in advance.
机译:色谱柱内部的流量决定性地取决于内部的填充床。无损X射线计算机断层扫描(CT)被用作一种新颖的测量技术,以可视化制备比例色谱柱中速度和轴向弥散系数的分布。结果表明,就HETP而言,球形颗粒似乎比不规则颗粒更有效,这在一定程度上是由于它们引起的流动更均匀的结果。利用CFD(计算流体动力学)模拟了根据填充床结构预测柱性能的模型,该模型除了通过CT获得的流体力学参数外还包括吸附等温线和传质参数。 CFD模拟的结果应有助于建立规则,以便为给定的分离任务提前选择合适的吸附材料。

著录项

  • 来源
    《Chemie Ingenieur Technik》 |2011年第2期|p.130-142|共13页
  • 作者单位

    Chair of Separation Science and Technology, Friedrich-Alexander University Erlangen-Nuremberg, Egerlandstraße 3, 91058 Erlangen, Germany;

    Chair of Separation Science and Technology, Friedrich-Alexander University Erlangen-Nuremberg, Egerlandstraße 3, 91058 Erlangen, Germany;

    Chair of Separation Science and Technology, Friedrich-Alexander University Erlangen-Nuremberg, Egerlandstraße 3, 91058 Erlangen, Germany;

    Chair of Separation Science and Technology, Friedrich-Alexander University Erlangen-Nuremberg, Egerlandstraße 3, 91058 Erlangen, Germany;

    Center for Energy Resources Engineering (CERE), Department of Chemical Engineering, Building 229, Technical University of Denmark, 2800 Lyngby, Denmark;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    CFD; Chromatography; column; computer tomography;

    机译:CFD;色谱;色谱柱;计算机断层扫描;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号