...
首页> 外文期刊>Canadian Geotechnical Journal >Analysis of the annual thermal response of an earth dam for the assessment of the hydraulic conductivity of its compacted till core
【24h】

Analysis of the annual thermal response of an earth dam for the assessment of the hydraulic conductivity of its compacted till core

机译:分析土坝的年度热响应,以评估其压实芯的水力传导率

获取原文
获取原文并翻译 | 示例
           

摘要

La chaleur transportée par infiltration le long des lignes d'écoulement peut servir de traceur naturel pour aider à détecter les conductivités hydrauliques contrastantes dans les barrages en terre. Des mesures thermiques ont été réalisées sur le barrage en terre du nord Québécois QA-01 de 94,5m de hauteur pour caractériser la distribution de la température à travers toute sa section. L'analyse de la réponse thermique annuelle du barrage montre clairement une zone de vitesses d'infiltration plus élevées dans le noyau de till compacté. Des approximations concernant la conductivité thermique croissante ont été faites au moyen d'un modèle thermique simple. Une modélisation numérique complémentaire a fourni une évaluation quantitative plus rigoureuse des schémas d'infiltration. Les calculs ont montré des conductivités 20 fois plus grandes que les valeurs attendues. Les mesures thermiques peuvent détecter des zones d'augmentation d'infiltration qui peuvent être reliées à l'érosion interne ou à d'autres facteurs tels que la variabilité des propriétés des sols due aux pratiques de construction. Le jugement concernant la cause de la présence d'une zone plus perméable dans un barrage et sa possible évolution ne devrait pas être basé seulement sur les mesures de la température.%Heat carried by the seepage water along hydraulic flow lines can serve as a natural tracer to help detect contrasting hydraulic conductivities in embankment dams. Thermal monitoring was realized on the 94.5m high QA-01 embankment dam in northern Quebec to characterize the temperature distribution across its entire section. The analysis of the annual thermal response of the dam clearly showed a zone of higher seepage velocities in the compacted till core. Approximations concerning the increased hydraulic conductivity were made using a simple thermal model. Complementary numerical modelling provided a more rigorous quantitative assessment of the seepage patterns. The calculations have shown hydraulic conductivities that are 20 times larger than the expected values. Thermal monitoring can detect zones of increased seepage, which can be related to internal erosion or other factors, such as the variability of the soil properties due to construction practices. Temperature measurements alone are not adequate to determine the cause of a permeable zone in a dam or to predict its possible evolution.
机译:渗透沿着流线传输的热量可以用作自然示踪剂,以帮助检测土坝中相反的水力传导率。在魁北克北部QA-01高94.5m的土坝上进行热测量,以表征整个剖面上的温度分布。对大坝年热响应的分析清楚地表明,压实的核心层中有较高的渗透率区域。使用简单的热模型可以得出增加导热系数的近似值。互补的数值模型对渗透模式进行了更严格的定量评估。计算结果表明电导率比预期值大20倍。热测量可以检测到渗透增加的区域,这可能与内部侵蚀或其他因素(例如,由于施工实践而导致的土壤性质的变化)有关。关于大坝渗透性较高的原因及其可能演变的判断不应仅基于温度测量。渗透水沿液压流线所携带的热量可以作为自然示踪剂可帮助检测堤坝中不同的水力传导率。对魁北克北部94.5m高的QA-01堤坝进行了热监测,以表征整个剖面的温度分布。对大坝年热响应的分析清楚地表明,在压实的核心层中有一个较高的渗流速度区域。使用简单的热模型可以得出有关增加的水力传导率的近似值。补充数值模拟对渗流模式进行了更严格的定量评估。计算表明,水力传导率比预期值大20倍。热监测可以发现渗流增加的区域,渗流可能与内部侵蚀或其他因素有关,例如由于施工习惯而导致的土壤性质变化。单靠温度测量不足以确定大坝中可渗透区域的成因或预测其可能的演变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号