首页> 外文期刊>Bulletin of Materials Science >Comparative corrosion study of Ag-Pd and Co-Cr alloys used in dental applications
【24h】

Comparative corrosion study of Ag-Pd and Co-Cr alloys used in dental applications

机译:牙科用Ag-Pd和Co-Cr合金的比较腐蚀研究

获取原文
获取原文并翻译 | 示例
           

摘要

The electrochemical behaviour of two Ag-Pd alloys (Unique White and Paliag) used in dental prosthetics construction for crowns and bridges and one Co-Cr alloy (Vitallium 2000) was studied in artificial saliva using the polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion resistance was evaluated by means of the corrosion currents value and by coulometric analysis. The open circuit potential of Ag-Pd are attributed to dealloying followed by surface enrichment with Ag and the possible formation of an insoluble AgCl surface film on the respective alloy surfaces. Our results have shown that these alloys have a somewhat good corrosion resistance in artificial saliva. The corrosion current densities of Unique White and Vitallium 2000 alloys were very low (∼100 nA/cm2). For Ag-Pd alloys, when increasing the content of Cu, corrosion resistance decreases. The passivation of all samples occurred spontaneously at the open circuit potential. The electrochemical properties of the spontaneously passivated electrodes at the open circuit potential were studied by EIS. The polarization resistance (R p) and the electrode capacitance (C dl) were determined. The polarization resistance of all the samples increases with the immersion time. The polarization resistances are largest for Unique White (Ag-Pd) and Vitallium 2000 (Co-Cr) alloys. Because the electrochemical behaviour of the Co-Cr alloy was compared with that of Ag-Pd alloy, this type of alloy may be a suitable alternative for use in the manufacture of fixed dental prostheses. The present study, though limited, has shown that electrochemical characteristics can be used to identify such alloys. Knowledge of the in vitro corrosion behaviour of these alloys may lead to better understanding of any biologically adverse effects in vitro.
机译:使用极化曲线和电化学阻抗谱(EIS)在人工唾液中研究了两种用于牙冠修复的Ag-Pd合金(Unique White和Paliag)和一种Co-Cr合金(Vitallium 2000)的电化学行为。 。通过腐蚀电流值和电量分析法评估了耐腐蚀性。 Ag-Pd的开路电位归因于脱合金,然后用Ag进行表面富集,并可能在各个合金表面上形成不溶性AgCl表面膜。我们的结果表明,这些合金在人造唾液中具有较好的耐腐蚀性。独特的White和Vitallium 2000合金的腐蚀电流密度非常低(〜100 nA / cm 2 )。对于Ag-Pd合金,当增加Cu的含量时,耐蚀性降低。所有样品的钝化都是在开路电位下自发发生的。用EIS研究了在开路电位下自发钝化电极的电化学性能。确定了极化电阻(R p )和电极电容(C dl )。所有样品的极化电阻都随着浸入时间的增加而增加。独特白色(Ag-Pd)和Vitallium 2000(Co-Cr)合金的极化电阻最大。因为将Co-Cr合金的电化学行为与Ag-Pd合金的电化学行为进行了比较,所以这种类型的合金可能是用于固定牙修复体的合适替代材料。本研究尽管有局限性,但已表明电化学特性可用于鉴定此类合金。这些合金的体外腐蚀行为的知识可能会导致更好地了解体外的任何生物学不利影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号