There is no standard size for samples used to establish water absorption (WA) by weight and volume. A total of 150 samples with five different diameters (54, 48, 42, 30 and 21 mm) were cored from sandstone, limestone and cement mortar with a length:diameter ratio between 2.0 and 2.5. The laboratory experiments were continued for 90 days, although some samples reached their maximum absorption at 43 and 60 days. The study has shown that WA values vary significantly with sample dimension and time. NX (54 mm) cores had the lowest WA values while 21 and 30 mm diameter cores gave the highest WA values. The difference between 24-h and 90-day WA values was greatest for the 21 mm cores.
机译:用于确定重量和体积吸水率(WA)的样品没有标准尺寸。总共150个具有五个不同直径(54、48、42、30和21毫米)的样品从砂岩,石灰石和水泥砂浆中取芯,长径比为2.0到2.5。实验室实验持续了90天,尽管有些样品在43天和60天达到最大吸收。研究表明,WA值随样本尺寸和时间的变化而显着变化。 NX(54 mm)磁芯的WA值最低,而直径21和30 mm的磁芯的WA值最高。 21毫米岩心的24小时和90天WA值之间的差异最大。