AIM: To study the influence of high-frequency electric surgical knives on healing of abdominal incision. METHODS: Two hundred and forty white rats were divided into 10(0), 10(2), 10(5), and 10(8) groups and rat models of abdominal operation were induced by using electric surgical knives and common lancets respectively. Then they were respectively given hypodermic injections of normal saline and 0.2 mL quantitative mixture of Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa at a concentration of 10(2), 10(5) and 10(8). On the basis of the animal experiment, 220 patients undergoing abdominal operations (above type II) were randomly allocated into one of following three groups: electric knife (EK, 93 cases), electro-coagulation (EC, 55 cases) and control (72 cases). High-frequency electric surgical knives were used to dissect abdominal tissues and electro-coagulation for hemostasis in EK group. Common lancets and electro-coagulation were applied in EC group. Common lancets and tying silksuture were used in the controls. RESULTS: In all the groups except group 10(0), infection rate of incisional wounds made by electric surgical knives were remarkably higher than that with common lancets. Furthermore, there were significant differences in groups 10(2), 10(5), and 10(8) (P<0.05), but not in group 10(0) (P>0.05) between EK and EC groups. Clinical studies showed a delayed wound healing in 16 cases (17.20%) in EK, 11 cases (16.36%) in EC and 2 cases (2.86%) in the control groups. A significant difference between EK and the control groups (chi2 = 8.57, P<0.01), and between EC and the control groups (chi2 = 5.66, P<0.05) was observed, but not between EK and EC (chi2 = 0.017, P>0.05). CONCLUSION: High-frequency electric knives may remarkably delay abdominal incision healing. Its application should be minimized so as to reduce the possibility of postoperative complications.
机译:目的:研究高频电刀对腹部切口愈合的影响。方法:将240只大白鼠分为10(0),10(2),10(5)和10(8)组,分别用电动手术刀和普通刺血针制作腹部手术的大鼠模型。然后分别给他们皮下注射生理盐水和浓度为10(2),10(5)和10(8)的0.2 mL大肠杆菌,金黄色葡萄球菌和铜绿假单胞菌定量混合物。根据动物实验,将220例接受腹部手术(II型以上)的患者随机分为以下三组之一:电刀(EK,93例),电凝(EC,55例)和对照组(72)情况)。 EK组采用高频电动手术刀解剖腹部组织并电凝止血。 EC组应用普通采血针和电凝。对照中使用普通刺血针和绑扎丝线。结果:除10(0)组外,其他所有组中,电动手术刀切开伤口的感染率均显着高于普通刺血针。此外,EK和EC组之间的10(2),10(5)和10(8)组之间存在显着差异(P <0.05),而10(0)组则没有显着差异(P> 0.05)。临床研究显示,EK的伤口愈合延迟为16例(17.20%),EC的为11例(16.36%),对照组为2例(2.86%)。观察到EK和对照组之间的差异(chi2 = 8.57,P <0.01),EC和对照组之间的差异(chi2 = 5.66,P <0.05),但EK和EC之间没有显着差异(chi2 = 0.017,P)。 > 0.05)。结论:高频电刀可能会明显延迟腹部切口的愈合。应尽量减少其应用,以减少术后并发症的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号