首页> 外文期刊>Building Services Engineering Research & Technology >The efficiency of a typical meteorological year and actual climatic data in the analysis of energy demand in buildings
【24h】

The efficiency of a typical meteorological year and actual climatic data in the analysis of energy demand in buildings

机译:典型气象年份和实际气候数据在分析建筑物能源需求中的效率

获取原文
获取原文并翻译 | 示例
           

摘要

A typical meteorological year (TMY) for Poland was developed in 2004, on the basis of climatic data collected from 1971 to 2000. Due to the observed tendency of global warming, the buildings' energy performance obtained with the use of TMY may differ from the actual heating and cooling demand. This research compares energy demand calculated using TMY and climatic data collected from 2001 to 2012. Calculations were made by means of a simulation computer program, designed for dynamic analyses of buildings and installation systems. The analyses concerned typical living quarters in a multifamily residential building located in Warsaw. According to the results, TMY is useful for estimating the heating demand of existing buildings. Cooling demand calculated with the use of TMY was, however, up to 37% lower in comparison with the mean cooling demand for subsequent years. This may distort the energy needs and indoor environment conditions in summer, and create discomfort while using existing and new buildings. Practical application: The paper presents comparison between energy demand calculated with the use of typical meteorological year (TMY) based on the climatic data from the period of 1971 to 2000, and real climatic data from subsequent 12 years, 2001-2012. There is substantial difference in the results presenting cooling demand in buildings evaluated with the use of both datasets. Unless national energy certification procedures are updated, this may cause serious faults in building design, due to incorrect assessment of internal conditions in new and existing buildings, and higher than expected energy use in summer.
机译:在1971年至2000年收集的气候数据的基础上,波兰于2004年制定了典型的气象年(TMY)。由于观察到的全球变暖趋势,使用TMY获得的建筑物的能源性能可能与实际的供热和制冷需求。这项研究比较了使用TMY计算的能源需求和2001年至2012年收集的气候数据。计算是通过模拟计算机程序进行的,该计算机程序旨在对建筑物和安装系统进行动态分析。分析涉及位于华沙的多户住宅楼中的典型居住区。根据结果​​,TMY可用于估算现有建筑物的供热需求。但是,与随后几年的平均制冷需求相比,使用TMY计算得出的制冷需求降低了37%。这可能会使夏季的能源需求和室内环境状况发生变化,并在使用现有建筑物和新建筑物时造成不适感。实际应用:本文介绍了根据1971年至2000年的气候数据,使用典型气象年(TMY)计算的能源需求与随后12年(2001年至2012年)的实际气候数据之间的比较。使用这两个数据集评估建筑物的制冷需求的结果存在很大差异。除非更新国家能源认证程序,否则可能会由于对新旧建筑物内部状况的不正确评估以及夏季的能源消耗高于预期而导致建筑物设计中的严重缺陷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号