首页> 外文期刊>Building and Environment >Using the adaptive model of thermal comfort for obtaining indoor neutral temperature: Findings from a field study in Hyderabad, India
【24h】

Using the adaptive model of thermal comfort for obtaining indoor neutral temperature: Findings from a field study in Hyderabad, India

机译:使用热舒适度的自适应模型获得室内中性温度:印度海德拉巴的实地研究结果

获取原文
获取原文并翻译 | 示例
       

摘要

There is a dearth of thermal comfort studies in India. It is aimed to investigate into the aspects of thermal comfort in Hyderabad and to identify the neutral temperature in residential environments. This was achieved through a thermal comfort field study in naturally ventilated apartment buildings conducted during summer and monsoon involving over 100 subjects. A total of 3962 datasets were collected covering their thermal responses and the measurement of the thermal environment. The comfort band (voting within -1 and +1), based on the field study, was found to be 26-32.45℃, with the neutral temperature at 29.23℃. This is way above the indoor temperature standards specified in Indian Codes. It was found that the regression neutral temperature and the globe temperature recorded when voting neutral converged when mean thermal sensation of the subjects was close to 0. This happened during the period of moderate temperature when the adaptive measures were adequate. The indoor temperatures recorded in roof-exposed (top floor) flats were higher than the lower floors. The thermal sensation and preference votes of subjects living in top floors were always higher. Consequently, their acceptance vote was also lower. It was found that the subjects living in top floor flats had a higher neutral temperature when the available adaptive opportunities were sufficient. This was due to their continuous exposure to a higher thermal regime due to much higher solar exposure. This study calls for special adaptive measures for roof-exposed flats to achieve neutrality at higher temperature.
机译:在印度,缺乏热舒适性研究。目的是调查海得拉巴的热舒适性,并确定居住环境中的中性温度。这是通过在夏季和季风期间对自然通风的公寓楼进行的热舒适性现场研究完成的,涉及100多个对象。总共收集了3962个数据集,涵盖了它们的热响应和热环境测量结果。根据现场研究,舒适带(在-1和+1范围内投票)为26-32.45℃,中性温度为29.23℃。这远高于印度法规中规定的室内温度标准。结果发现,当受试者的平均热感接近于0时,投票中性时记录的回归中性温度和地球温度会收敛。这发生在适度温度期间,如果采取了适当的措施。屋顶暴露(顶层)房间中记录的室内温度高于底层。生活在顶层的受试者的热感和偏好票总是更高。因此,他们的接受投票也更低。发现当可用的适应机会足够时,住在顶层公寓的受试者具有较高的中性温度。这是由于它们由于暴露于更高的太阳光下而持续暴露于更高的热态。这项研究要求对暴露于屋顶的公寓采取特殊的适应性措施,以在高温下达到中性。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号