To save energy ceilings towards a ventilated cold attic space are normally insulated. In Denmark the insulation material thickness and type varies but the common used insulation material type is mineral wool or cellulose-based insulation. Furthermore, some attics have vapour barriers, whereas others do not or only have poorly sealed vapour barriers. The effect of these variations on the humidity conditions in cold ventilated attics was investigated in preparation for evaluating the existing recommendations on when and how to add additional insulation to ventilated attics to reduce energy consumption. The investigation has been done by examining and measuring the relative humidity and temperature for at least one year in 34 attics in inhabited single-family houses. In addition, outdoor and indoor temperatures and relative humidity were measured. The results were divided into different groups based on the vapour barrier type, amount of insulation, and insulation material type. Most of the attics were ventilated according to the Danish recommendations. Contrary to the expectations, the thickness of insulation material had no effect on the temperature or relative humidity in the attic. The type of insulation material or the presence of a vapour barrier also did not have any noticeable effect. Apparently, the air change rate (ACH) is more important than the investigated parameters. Combined with previously published results from controlled full-scale experiments, the results from this study are valuable input to new recommendations on how to apply additional insulation in existing ventilated attics.
机译:为了节省能量,天花板通常朝向通风的阁楼空间进行隔热。在丹麦,隔热材料的厚度和类型各不相同,但常用的隔热材料类型是矿棉或纤维素基隔热材料。此外,一些阁楼有防潮层,而另一些则没有或只有不好的防潮层。在准备评估何时以及如何在通风阁楼上增加额外的隔热材料以减少能耗的现有建议时,研究了这些变化对冷通风阁楼湿度条件的影响。通过在居住的单户住宅中的34个阁楼中检查和测量至少一年的相对湿度和温度来进行调查。另外,还测量了室外和室内的温度和相对湿度。根据防潮层类型,绝缘量和绝缘材料类型将结果分为不同的组。大部分阁楼都按照丹麦的建议通风。与预期相反,绝缘材料的厚度对阁楼中的温度或相对湿度没有影响。绝缘材料的类型或防潮层的影响也没有明显的影响。显然,换气速率(ACH)比研究的参数更重要。结合先前发布的受控全尺寸实验结果,该研究结果为有关如何在现有通风阁楼中应用附加隔热材料的新建议提供了宝贵的信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号