This paper presents an experimental study on the indoor air temperature near residential facades in naturally ventilated buildings in tropical climate of Singapore. Four residential sites (Site A-D) with different design features were selected for investigation. Indoor measurements were conducted at locations 30-cm away from the facades.Field measurement results showed that windows are of great significance to indoor thermal environment. In vacant units, the peak indoor air temperature reached 44 degrees C near a large west-facing window at Site A on sunny afternoon, when windows were kept closed and window-to-wall ratio (WWR) was 0.9. Air temperature near the closed window was lowered by 4.1 degrees C in the afternoon when WWR was reduced from 0.9 to 0.6. Moreover, window openings can effectively lower the indoor air temperature. At Site B, indoor air near a closed window was 7.6 degrees C hotter than that near an open window with the same orientation and window, and the average temperature difference reached 3.2 degrees C during daytime (7:00-19:00). In occupied units, air temperature near the north-facing facade was found 4.7 degrees C higher than that near the east-facing facade in July at Site D, due the sun path in Singapore. The percentages of time with indoor comfortable conditions were evaluated using the criterion for Asian residential buildings in summer. It was found that the acceptable time percentages were no less than 80% for indoor locations with daytime or occasional window ventilation. Facade design recommendations were proposed to reduce indoor air temperature and improve indoor thermal comfort in tropical climate.
机译:本文提出了一项在新加坡热带气候下自然通风建筑中住宅立面附近室内空气温度的实验研究。选择了四个具有不同设计特征的住宅用地(A-D地)进行调查。在距立面30厘米处进行室内测量,现场测量结果表明窗户对室内热环境具有重要意义。在空置单位中,在阳光明媚的下午,在站点A的一个朝西的大窗户附近,室内空气峰值温度达到44摄氏度,此时窗户保持关闭状态,窗墙比(WWR)为0.9。当WWR从0.9降低到0.6时,下午关闭的窗户附近的空气温度降低了4.1摄氏度。而且,窗户的开口可以有效地降低室内空气温度。在站点B,在相同方向和窗口的情况下,关闭的窗户附近的室内空气温度比打开的窗户附近的温度高7.6摄氏度,白天(7:00-19:00)的平均温差达到3.2摄氏度。在被占领的单位中,由于新加坡的阳光路径,发现七月在站点D朝北立面附近的气温比向东立面附近的气温高4.7摄氏度。使用夏季亚洲住宅建筑的标准评估室内舒适条件下的时间百分比。发现在白天或偶尔有窗户通风的室内场所,可接受的时间百分比不少于80%。提出了外墙设计建议,以降低室内空气温度并改善热带气候下的室内热舒适性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号