A real-time microcomputerized muscle fatigue monitor based on the median frequency shift of the electromyographic signal, computed via the fast Fourier transform, is discussed. For the ten subjects performing an isotonic and isometric trunk extension task on two separate days, preliminary results suggest a repeatable linear decrease in median frequency as a function of time.
机译:讨论了基于通过快速傅里叶变换计算的肌电信号中值频移的实时微计算机肌肉疲劳监测器。对于在两天中分别执行等张和等距躯干伸展任务的十名受试者,初步结果表明,中位频率随时间呈线性重复下降。