首页> 外文期刊>IEEE Transactions on Biomedical Engineering >pH measurements with an ion sensitive field effect transistor in the mouth of patients with xerostomia
【24h】

pH measurements with an ion sensitive field effect transistor in the mouth of patients with xerostomia

机译:用口干症患者口中的离子敏感场效应晶体管进行pH测量

获取原文
获取原文并翻译 | 示例
           

摘要

A transistor pH electrode (ion-sensitive field-effect transistor), placed in the upper dentures of xerostomia patients and five healthy volunteers, was used to register pH changes in five-, six-, and seven-day-old dental plaque. A mouth rinse with a 10% sucrose solution caused a pH fall of about three-decades. A significant difference in the duration of critical plaque pH was observed; in xerostomia patients, a 10% longer period of pH >5.7 was registered during 60 min following a sucrose rinse. Normal oral functions were not influenced by the denture containing the integrated electrode. Both in vitro and in vivo tests showed remarkable electrode stability. Materials and measurement methods are described.
机译:放置在口腔干燥症患者和五名健康志愿者的义齿中的晶体管pH电极(离子敏感场效应晶体管)用于记录五天,六天和七天大的牙菌斑的pH变化。用10%蔗糖溶液漱口会导致pH值下降约三个十年。观察到临界噬菌斑pH值的持续时间有显着差异。在口腔干燥症患者中,蔗糖冲洗后60分钟内,pH> 5.7的时间延长了10%。正常的口腔功能不受包含集成电极的义齿的影响。体外和体内试验均显示出显着的电极稳定性。描述了材料和测量方法。