Presents a method for determining activation time delays in unipolar cardiac mapping data to resolutions considerably smaller than the sample interval. The method involves taking two filtered, differentiated electrograms and computing the Hilbert transform of their cross correlation, which exhibits a negative-to-positive zero crossing at the delay time between the signals. Simultaneous endocardial/epicardial recordings of sinus rhythm were made in the swine right atrium using identical, precisely superpositioned electrode arrays. Data were amplified, lowpass filtered, and digitized at 1000 Hz. A window of data was chosen around each electrogram in an endocardial/epicardial electrogram pair. The windowed electrograms were differentiated and highpass filtered, and the Hilbert transform of the cross correlation between the electrograms was computed. The activation time delay was taken to be the first negative-to-positive zero crossing. Average activation time delays (/spl plusmn/SD) were computed for 4-s sinus rhythm recordings from each endocardial/epicardial electrode pair. For a representative site, the average transmural activation time delay was 0.71/spl plusmn/0.06 ms (n=10 electrograms). Time delays estimated using the Hilbert transform method were compared with time delays estimated using the maximum negative slope criterion. The Hilbert transform results exhibited much smaller standard deviations, indicating that the Hilbert transform method may produce more accurate time delay estimates than the maximum negative slope method.
机译:提出了一种方法,用于确定单极心脏映射数据中的激活时间延迟,使其分辨率大大小于采样间隔。该方法涉及获取两个经过滤波的微分电图,并计算它们的互相关的希尔伯特变换,该变换在信号之间的延迟时间上呈现出负到正的零交叉。使用相同的,精确叠置的电极阵列在猪右心房同时记录窦性心律的心内膜/心外膜。数据被放大,低通滤波并以1000 Hz数字化。在心内膜/心外膜电图对中每个电图周围选择一个数据窗口。区分开窗的电图并进行高通滤波,并计算电图之间的互相关性的希尔伯特变换。激活时间延迟被认为是第一个负到正的零交叉。计算每个心内膜/心外膜电极对的4-s窦性心律记录的平均激活时间延迟(/ spl plusmn / SD)。对于代表性的部位,平均经壁激活时间延迟为0.71 / spl plusmn / 0.06 ms(n = 10幅电描记图)。将使用希尔伯特变换方法估算的时延与使用最大负斜率标准估算的时延进行比较。希尔伯特变换结果显示出较小的标准偏差,这表明希尔伯特变换方法可能比最大负斜率方法产生更准确的时间延迟估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号