Design and implementation of a hands-free electrolarynx device controlled by neck strap muscle electromyographic activity

机译:由颈带肌肉肌电图活动控制的免提电喉装置的设计与实现

获取原文
获取原文并翻译 | 示例
           

摘要

The electrolarynx (EL) voice prosthesis is widely used, but suffers from the inconvenience of requiring manual control. Therefore, a hands-free EL triggered by neck muscle electromyographic (EMG) activity was developed (EMG-EL). Signal processing circuitry in a belt-mounted control unit transforms EMG activity into control signals for initiation and termination of voicing. These control signals are then fed to an EL held against the neck by an inconspicuous brace. Performance of the EMG-EL was evaluated by comparison to normal voice, manual EL voice, and tracheo-esophageal (TE) voice in a series of reaction time experiments in seven normal subjects and one laryngectomy patient. The normal subjects produced voice initiation with the EMG-EL that was as fast as both normal voice and the manual EL. The laryngectomy subject produced voice initiation that was slower than with the manual EL, but faster than with TE voice. Voice termination with the EMG-EL was slower than normal voice for the normal subjects, but not significantly different than with the manual EL. The laryngectomy subject produced voice termination with the EMG-EL that was slower than with TE or manual EL. The EMG-EL threshold was set at 10% of the range of vocal-related EMG activity above baseline. Simulations of EMG-EL behavior showed that the 10% threshold was not significantly different from the optimum threshold produced through the process of error minimization. The EMG-EL voice reaction time appears to be adequate for use in a day-to-day conversation.
机译:电喉(EL)语音假体已被广泛使用,但需要手动控制带来不便。因此,开发了由颈肌肌电图(EMG)活动触发的免提EL(EMG-EL)。安装在皮带上的控制单元中的信号处理电路将EMG活动转换为控制信号,以启动和终止发声。然后,这些控制信号通过不起眼的支架被馈送到紧靠脖子的EL。通过在七个正常受试者和一名喉切除患者的一系列反应时间实验中,通过与正常语音,手动EL语音和气管食管(TE)语音进行比较,评估了EMG-EL的性能。正常受试者使用EMG-EL进行语音启动,其速度与普通语音和手动EL一样快。喉切除术对象产生的语音启动比手动EL慢,但比TE语音快。对于正常对象,EMG-EL的语音终止比正常语音慢,但与手动EL的语音终止没有显着差异。喉切除术对象的EMG-EL声音终止比TE或手动EL慢。 EMG-EL阈值设置为高于基线的与声音相关的EMG活动范围的10%。 EMG-EL行为的仿真表明,10%阈值与通过误差最小化过程产生的最佳阈值没有显着差异。 EMG-EL语音反应时间似乎足够用于日常对话。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号