...
首页> 外文期刊>IEEE Transactions on Biomedical Engineering >A Breast-Specific MR Guided Focused Ultrasound Platform and Treatment Protocol: First-in-Human Technical Evaluation
【24h】

A Breast-Specific MR Guided Focused Ultrasound Platform and Treatment Protocol: First-in-Human Technical Evaluation

机译:乳房特定的MR引导聚焦超声波平台和治疗方案:第一中的技术评估

获取原文
获取原文并翻译 | 示例

摘要

Objective: This paper presents and evaluates a breast-specific magnetic resonance guided focused ultrasound (MRgFUS) system. A first-in-human evaluation demonstrates the novel hardware, a sophisticated tumor targeting algorithm and a volumetric magnetic resonance imaging (MRI) protocol. Methods: At the time of submission, N = 10 patients with non-palpable T0 stage breast cancer have been treated with the breast MRgFUS system. The described tumor targeting algorithm is evaluated both with a phantom test and in vivo during the breast MRgFUS treatments. Treatments were planned and monitored using volumetric MR-acoustic radiation force imaging (MR-ARFI) and temperature imaging (MRTI). Results: Successful technical treatments were achieved in 80% of the patients. All patients underwent the treatment with no sedation and 60% of participants had analgesic support. The total MR treatment time ranged from 73 to 114 minutes. Mean error between desired and achieved targeting in a phantom was 2.9 +/- 1.8 mm while 6.2 +/- 1.9 mm was achieved in patient studies, assessed either with MRTI or MR-ARFI measurements. MRTI and MR-ARFI were successful in 60% and 70% of patients, respectively. Conclusion: The targeting accuracy allows the accurate placement of the focal spot using electronic steering capabilities of the transducer. The use of both volumetric MRTI and MR-ARFI provides complementary treatment planning and monitoring information during the treatment, allowing the treatment of all breast anatomies, including homogeneously fatty breasts.
机译:目的:本文呈现并评估乳房特定磁共振引导聚焦超声(MRGFUS)系统。第一人类评估证明了新颖的硬件,复杂的肿瘤靶向算法和体积磁共振成像(MRI)方案。方法:在提交时,N = 10例患有乳房MRGFUS系统的非明显T0阶段乳腺癌患者。所述肿瘤靶向算法在乳房MRGFU治疗期间用幻影测试和体内进行评估。使用体积Mr声辐射力成像(MRFI)和温度成像(MRTI)进行计划和监测治疗。结果:80%患者成功的技术治疗方法。所有患者均接受的治疗没有镇静,60%的参与者具有镇痛药。先生治疗时间为73至114分钟。在患者研究中,在患者中,在患者中靶向的所需和靶向之间的平均误差是2.9 +/- 1.8 mm,患者研究中达到6.2 +/- 1.9mm,用MRTI或MR-ARFI测量评估。 MRTI和ARFI分别在60%和70%的患者中成功。结论:靶向精度允许使用换能器的电子转向能力精确放置焦点。在治疗过程中使用体积MRTI和MR-ARFI的使用提供了互补的治疗计划和监测信息,允许治疗所有乳房解剖,包括均匀脂肪乳房。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号