Objective: A novel method is developed to identify ablation targets for the catheter treatment of ventricular tachycardia (VT). Methods: The method is based on pace-mapping, which is a validated technique to determine the catheter ablation targets. Conventionally, it consists of stimulating the heart ventricle from various sites and comparing the resulting activation pathways to that of a clinical VT by the analysis of surface electrocardiograms (ECG). In this paper, a novel pace-mapping method is presented, which does not require a reference ECG recording of the VT. A three-dimensional correlation gradient map is reconstructed by semiautomatic analysis of ECG morphological changes within the network of pace-mapping sites. In these maps, abnormal points are identified by high correlation gradient values (i.e., corresponding to slow propagation of the electric influx, as in the core of the reentrant VT circuit). The relation between the conventional and reference-less method is described theoretically and evaluated in a retrospective study including 24 VT ablation procedures. Results: The "reference-less" method was able to identify normal points with a high accuracy (negative predictive value: NPV = 97%), and to detect more abnormal points, as predicted by the theory. Correlation gradients computed by the proposed method were significantly higher in ablation zones than in other zones of the ventricle (p < 10(-12)), indicating excellent prediction of the ablation targets. Significance: The reference-less method might either be used in complement of the conventional method or to treat patients in whom VT cannot be induced during the intervention.
机译:目的:开发一种新的方法来确定导管治疗室性心动过速(VT)的消融目标。方法:该方法基于起搏图,这是一种确定导管消融目标的有效技术。通常,它包括从各个部位刺激心室,并通过分析表面心电图(ECG)将所得的激活途径与临床VT的激活途径进行比较。在本文中,提出了一种新颖的速度映射方法,该方法不需要VT的参考ECG记录。通过对步调图站点网络内的ECG形态变化进行半自动分析,重建了三维相关梯度图。在这些图中,异常点由高相关梯度值标识(即,对应于电涌的缓慢传播,如折返VT电路的核心部分)。理论上描述了传统方法与无参考方法之间的关系,并在一项回顾性研究中对其进行了评估,该研究包括24种VT消融程序。结果:“无参考”方法能够以较高的准确度识别正常点(负预测值:NPV = 97%),并且可以检测到更多异常点,如理论所预测的那样。通过提出的方法计算的相关梯度在消融区域中明显高于在心室的其他区域(p <10(-12)),表明消融目标的出色预测。启示:无参考方法可以作为传统方法的补充,也可以用于治疗在干预期间无法诱发室速的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号