首页> 外文期刊>Biomedical Chromatography >Determination of 3-hydroxy pterocarpan, a novel osteogenic compound in rat plasma by liquid chromatography–tandem mass spectrometry: application to pharmacokinetics study?
【24h】

Determination of 3-hydroxy pterocarpan, a novel osteogenic compound in rat plasma by liquid chromatography–tandem mass spectrometry: application to pharmacokinetics study?

机译:液相色谱-串联质谱法测定大鼠血浆中一种新型成骨化合物3-羟基翼果聚糖:在药代动力学研究中的应用?

获取原文
获取原文并翻译 | 示例

摘要

A rapid, sensitive and selective LC-MS/MS method for the quantitative analysis of 3-hydroxy pterocarpan (S006-1709) in female rat plasma has been developed and validated. A Discovery RP18 column was used for the chromatographic elution using acetonitrile and 0.1% acetic acid in water as mobile phase (80:20 v/v) at the flow rate of 0.5?mL/min. MS/MS analysis was performed using a triple quadrupole mass spectrometer with electrospray ionization in negative ion mode using biochanin as an internal standard (IS). Extraction of S006-1709 and IS from rat plasma was done by liquid–liquid extraction method using diethyl ether. The LC-MS/MS method was sensitive with 1.95?ng/mL as the limit of detection and 3.9?ng/mL as the lower limit of quantification. The method was linear in the concentration range of 3.9–1000?ng/mL. The percentage bias for intraday and interday accuracy was not greater than 4.2 and the %RSD for intraday and interday precision was not greater than 13.2. The recoveries of S006-1709 and IS were 73.9–79.3 and 85.7%, respectively. S006-1709 was found to be stable in various stability studies. The validated LC-MS/MS method was successfully applied for the oral pharmacokinetics study of S006-1709 at 10?mg/kg in female Sprague–Dawley rats. Copyright ? 2010 John Wiley & Sons, Ltd.
机译:已经开发并验证了一种快速,灵敏且选择性的LC-MS / MS方法,用于定量分析雌性大鼠血浆中的3-羟基翼果烷(S006-1709)。使用Discovery RP 18 色谱柱进行色谱洗脱,使用乙腈和0.1%的乙酸水溶液作为流动相(80:20 v / v),流速为0.5?mL / min。 MS / MS分析是使用三重四极杆质谱仪进行的,其中使用生物chanin作为内标(IS)以负离子模式进行电喷雾电离。用乙醚液液萃取法从大鼠血浆中提取S006-1709和IS。 LC-MS / MS方法灵敏度高,检测限为1.95?ng / mL,定量下限为3.9?ng / mL。该方法在3.9–1000?ng / mL的浓度范围内是线性的。日内和日间准确性的百分比偏差不大于4.2,日内和日间准确性的%RSD不大于13.2。 S006-1709和IS的回收率分别为73.9-79.3和85.7%。在各种稳定性研究中发现S006-1709是稳定的。经过验证的LC-MS / MS方法已成功地以10?mg / kg的剂量在雌性Sprague–Dawley大鼠中用于S006-1709的口服药代动力学研究。版权? 2010 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号